Patton electronic user manual Model 552-D6

Models: 552

1 5
Download 5 pages 62.99 Kb
Page 4
Image 4

 

Model 552-D6

Pins Protected:

Pins 2, 3, 4, 5, 6, 7 on the RJ-45 Interface

 

Pins 1, 2, 3, 4, 5, 6 on the RJ-11 Interface

Clamping Voltage:

310 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec;

 

250A with an 8/20 µsec pulse

Protection Mode:

Common Mode Pins 2, 3, 4, 5, 6, 7 to

 

shielding braid

 

Differential Mode Pins 2, 3, 4, 5, 6, 7

 

Model 552-D8

Pins Protected:

Pins 1, 2, 3, 4, 5, 6, 7, 8

Clamping Voltage:

310 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec;

 

250A with an 8/20 µsec pulse

Protection Mode:

Common Mode Pins 1, 2, 3, 4, 5, 6, 7, 8 to

 

shielding braid

 

Differential Mode Pins 1, 2, 3, 4, 5, 6, 7, 8

 

Model 552-T1 and 552-E1

Pins Protected:

Pins 1, 2, 4, 5

Clamping Voltage:

62 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec;

 

400A with an 8/20 µsec pulse

Protection Mode:

Common Mode Pins 1, 2, 4, 5 to shielding

 

braid

 

Differential Mode Pins 1, 2, 4, 5

 

Model 552--E1 CX

Pins Protected:

All shields and center pins

Clamping Voltage:

62 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec;

 

400A with an 8/20 µsec pulse

Protection Mode:

Common Mode Center Pins and Shield to

 

shielding braids

 

Differential Mode Center Pins to Shields

 

Model 552-L4 and 552-U

Pins Protected:

Pins 3, 4, 5, 6

Clamping Voltage:

62 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec;

 

400A with an 8/20 µsec pulse

Protection Mode:

Common Mode pins 3, 4, 5, 6 to shielding

 

braid

 

Differential Mode Pins 3, 4 5, and 6

 

Model 552-L8* and 552-ST

Pins Protected:

Pins 1, 2, 3, 4, 5, 6, 7, 8

Clamping Voltage:

62 Volts in 500 nsec

Surge Capacity:

1500 Watts for 1 msec

 

400 A with an 8/20 µsec pulse

Protection Mode:

Common Mode pins 1, 2, 3, 4, 5, 6, 7, 8 to

 

shielding braid

 

Differential Mode Pins 1, 2, 3, 4, 5, 6, 7, 8

*NOTE: In addition to protecting leased line modem interfaces, the Model 552-L8 may also be used to protect DDS, T1, E1, ISDN PRI, and ISDN BRI “U” and “ST” interfaces.

Copyright © 1997

Patton Electronics Company

All Rights Reserved

Page 4
Image 4
Patton electronic user manual Model 552-D6