APPENDIX A
SPECIFICATIONS
Environment:
Connectors: RJ-45 Female
Response Time: Clamped to 13 V after 0.1 µs
Characteristic Impedance: 100 Ohms
NEXT Loss: Model 570 - worst pair Better than
Surge Clamp Voltage: Model 570 - 13 V max with 1 KV Input; Model 580 - 15 V max with 2 KV Input
Surge Rating: IEC 801.5 Standard Level
DC Clamp Voltage: Common Mode to Gnd, each line
7.5 V @ 50 mA; Differential mode, per pair 8.1 V @ 50 mA
Insertion Loss: Less than 0.4 dB at 100 MHz (including connector)
Return Loss: Better than 14 dB
Group Delay: None, 1 MHz to 100 MHz
Series Resistance: Less than 400 milliohms
Grounding: External ground strap provides separate
Dimensions: 2.25" x 1.69" x .75"
APPENDIX B
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
COMPLIANCE
Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Effective January 1996 the European Economic Community will require that all electronic devices be tested and comply with all applicable International standards relating to the product type and category of use. Electromagetic Compatibility Directive 89/336/EEC specifically addresses communication line surge protection devices, since conformity to immunity standard
IEC
Class | Sym. Lines Coupling Mode |
| |
|
|
1 | 1.0 kV |
| 24 A |
2 | 1.0 kV |
| 24 A |
3 | 2.0 kV |
| 48 A |
4 | (n/a) |
| (n/a) |
5 | 4.0 Kv |
| 95 A |
Wave | (1.2 x 50 µs) |
Forms | (1.2 x 50 µs) |
|
|
Figure
*Note: All test results are for the Model 570/580 alone, not including the standard 6” patch cable that is normally shipped with the unit.