Front Panel

(4) Protect Indicators

(5)AC Power Switch

(6)Cooling Air Vent

4

6

5

4

6

5

Upon powering up the unit, the Protect LEDs illuminate momentarily and then turn off one channel at a time and then remain off. During normal operation, an over-current condition can occur if the amplifier is being overdriven to the point where clipping is continuous or from a short circuit in the speaker output. The Protect LED will illuminate red when one of these conditions occurs.

The internal temperature of CMSeries amplifiers is 65º celsius. Should the unit exceed this temperature, the amplifier will go into thermal protect mode (generally, this would only occur if the internal fan fails). If the amplifier has a thermal fault condition‚ all LEDs will illuminate. When the amplifier cools down, the unit will restart automatically.

CM Series power amplifiers have a standard AC switch on the front panel.

Warning: The power switch does not break both sides of the line and under certain conditions hazardous energy can be present when the switch is in the OFF position.

The CM Series is designed to operate under extreme conditions. The front-panel design features a duct that allows air to be drawn in by the fan, circulated through the removable filter (for cleaning) and finally dispersing out the sides of the unit. The openings on the front and sides of the unit should never be blocked. It is recommended that the removable filter be cleaned with compressed air.