Peavey PV 3800 manual Turn-On/Turn-OffProtection, RAMPUP Signal Control, Protection Features

Models: PV 3800

1 20
Download 20 pages 18.96 Kb
Page 15
Image 15
Turn-On/Turn-Off Protection

Protection Features

Turn-On/Turn-Off Protection

At power-up, the amplifier stays in the protect mode with outputs disconnected for approximately six seconds while the power supplies charge and stabilize. While the output relays are open, the DDT™ LEDs light. When power is removed, the speaker loads immediately disconnect so that no thumps or pops are heard.

RAMPUP™ Signal Control

Whenever a PV® 3800 amplifier powers up or comes out of a protect mode, the RAMPUP circuit activates. While the speakers are disconnected, the RAMPUP circuit fully attenuates the signal and activates the DDT LED. After the output relay closes, the signal slowly and gradually raises to its set level. The PWR LED will illuminate and the DDT LED will turn off when the signal is no longer attenuated. The RAMPUP Signal Control circuit has some important advantages over conventional instant-on circuits:

1.If a signal is present during power-up (or when coming out of protect), the speakers are spared a sudden, potentially damaging burst of audio power.

2.Because the gain is reduced until after the output relay closes, no arcing occurs at the contacts. This extends the contacts’ useful life.

15

Page 15
Image 15
Peavey PV 3800 manual Turn-On/Turn-OffProtection, RAMPUP Signal Control, Protection Features