ISSUED: 04-08-08 SHEET #: 055-9094-2 06-06-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
7 of 16
Drill six 1/2" holes through drywall and metal studs. NOTE: It may be necessary to drill 5/32" pilot holes prior to
drilling 1/2" holes.
Refer to instruction sheet included with Peerless accessory kit ACC 615 for metal studs to install togglers.
Fasten two 1/4-20 x 2-1/2" screws into top mounting holes leaving a .25" of exposed thread on each as shown in
fig. 2.4. Hook wall mount assembly (A) onto 1/4-20 x 2-1/2" screws.
Fasten four 1/4-20 x 2-1/2" screws into wall mount assembly (A) as shown in fig. 2.5. Make sure that the wall mount
assembly (A) is level, tighten all six 1/4-20 x 2-1/2" screws.
Drywall must be 1/2" or thicker, and metal stud must be 24 gauge or thicker.
Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
WARNING

Installation to Metal Stud Wall (Metal Stud Accessory Kit ACC 615 Required)

TOGGLER
Afig. 2.4
1/4-20 X 2-1/2" PHILLIPS SCREWS
2
.25"

fig. 2.5

A
CARRIAGE
CARRIAGE
1/4-20 X 2-1/2" PHILLIPS SCREWS