4 of 6 ISSUED: 06-04-10 SHEET #: 120-9084-1

Installation to Double Wood Stud Wall

Wall plate (A) can be mounted to four studs that are 16" apart. Use a stud nder to locate the edges of the studs.
Use of an edge-to-edge stud nder is highly recommended. Based on their edges, draw a vertical line down each
stud’s center. Place wall plate on wall as a template. Level plate, and mark the center of the four mounting holes.
Make sure that the mounting holes are on the stud center lines. Drill four 5/32" (4 mm) dia. holes 2.5" (65 mm)
deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (F) as shown in gure 2.2.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations.
WARNING

g. 2.1

g. 2.2

ASTUD
F
A

2