5 of 34 ISSUED: 11-09-07 SHEET #: 202-9253-4 08-31-10
Make sure that wall plate (AA) is level, use it as a
template to mark six mounting holes. The top mounting
slots should be located above the desired screen center
as indicated by dimension X in gure 1.1 and charts on
pages 4. Drill six 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Insert anchors (DD) in holes
ush with wall as shown (right). Place wall plate over
anchors and secure with #14 x 2.5" screws (CC). Level,
then tighten all fasteners.
1
CC
AA
DD
SOLID CONCRETE
CINDER BLOCK
Installation to Solid Concrete or Cinder Block
When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 speci cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
dry wall plaster/
dry wall
concrete concrete
1
3
2
DD
Drill holes and insert anchors (DD).
Place plate (AA) over anchors (DD) and secure with screws (CC).
Tighten all fasteners.
AA
DD
CC
concrete
surface
Tighten screws so that wall plate is rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
Always attach concrete expansion anchors directly
to load-bearing concrete.
Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
nishing material. If mounting to concrete surfaces
covered with a nishing surface is unavoidable (not
evaluated by UL), the nishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied
by installer (not evaluated by UL).