4 of 34 ISSUED: 11-09-07 SHEET #: 202-9253-4 08-31-10
CC
AA
g. 1.2
Installation to Triple Wood Stud Wall
Wall plate (AA) can be mounted to three studs that are 16" (41 cm) apart. Use a stud nder to locate the edges
of the studs. Use of an edge-to-edge stud nder is highly recommended. Based on their edges, draw a vertical
line down each stud’s center. Place wall plate on wall as a template. The top mounting slots should be located "X"
distance above the desired screen center as shown in gure 1.1 and chart 1. Level plate, and mark the center of
the six mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia.
holes 2.5" (64 mm) deep. Make sure that the wall plate is level, secure it using six #14 x 2.5" wood screws (CC) as
shown in gure 1.2.
Skip to step 2.
NOTE: Wall plate may be mounted up to 6" (152 mm) off center as shown in gure 1.1.
CS = center of screen g. 1.1
STUD
AA
6"
(152 mm)
6"
(152 mm)
Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
WARNING
1
CS "X"

"X" Distance

SF670 and SWS510 models .75" (19 mm)

SF680 models 3.75" (95 mm)