5.0 SPECIFICATIONS

ELECTRICAL
Enclosure Back Box
Input Voltage: 24 VAC or 120 VAC
Power Requirements
Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives
Blower
(continuous duty): One (1) at 33 cfm, 6.7 watts, 120 VAC @ 60 Hz
Heaters
120 VAC: 135 watts total
Thermostatically controlled; activates ON at 40°F (4.4°C) and
OFF at 60°F (15.56°C)
Power Cord: Not supplied; use 3-wire grounded, 18 Awg minimum for 120
VAC supply input
Power Cable: Not supplied; must conform to local and national electrical
codes
GENERAL
Enclosure
Environment: Indoor or outdoor (depending on model ordered)
Dimensions: See Figures 7 and 8
Construction
Back box: Aluminum
Cap: Aluminum
Bezel: Aluminum
Trim Ring: ABS/aluminum
Finish
Outdoor: BB08E211 Light gray
Indoor: BB08A120 White (back box) and eggshell white (face
plate, trim ring and bezel)
BB08E120 Black
Temperature
Indoor Models: 32° to 120°F (0° to 48.89°C)
Outdoor Models: -10° to 120°F (-23.33° to 48.89°C)

(Design and product specifications subject to change without notice.)

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union