C1301M (6/05) 31

Quick Programming Guide

(See Page 9)

WIPER

The following EHXM unit models feature a window wiper to clear moisture from the window of the
enclosure:
EHXM31C22-2 EHXM31C22-2X
EHXM31C22-7 EHXM31C22-7X
EHXM31CBW23-2 EHXM31CBW23-2X
EHXM31CBW23-7 EHXM31CBW23-7X

NOTE:

The Wiper menu is only available on the above models. To check the unit model refer to the

System Information

section of this manual.

WIPER CONTROL

This feature programs the on/off control for the wiper. There are two available settings for wiper
control, AUX 1 and Preset 86. If the wiper control is programmed for AUX 1, the wiper will operate
when AUX 1 is accessed. If the wiper control is set to Preset 86, selecting preset 86 on your
controller will turn the wiper on/off.

WIPER MODE

Wiper mode determines how the wiper will act after the wiper control is turned on/off. There are
two modes of operation for wiper mode:
MOMENTARY (default) Programs the wiper to move across the enclosure window once and
then back to its starting position.
CONTINUOUS Programs the wiper to operate continually after the wiper is turned
on. The wiper will continue to operate until the wiper control (AUX 1
or preset 86) is pressed again or until the programmed wiper time is
completed.

WIPER DWELL

The wiper can be programmed to wipe the enclosure window every 2 to 30 seconds. This setting
only works when the wiper is programmed for continuous mode. The dwell time can be programmed
from 2 to 30 seconds.

WIPER TIME

Wiper time programs how long the wiper will be on before it automatically shuts off. This setting
only works when the wiper is programmed for continuous mode. Wiper time can be programmed
from 60 to 1,440 minutes (1 to 24 hours).

NOTE:

CM9700 Matrix Systems Only – For the wiper to operate in continuous mode, the AUX 1
function in the camera file must be set to latching in the CM9700-MGR. If the AUX 1 camera file is
not latching, the wiper will only operate in momentary mode, even if the system wiper is
programmed for continuous operation. Refer to the CM9700-MGR Software Guide for instructions.
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
UNIT SETTINGS
WIPER CONTROL AUX 1
WIPER MODE CONTINUOUS
WIPER DWELL (SECS) 2
WIPER TIME (MINS) 60
<SET WASHER SEQUENCE>
BACK
EXIT
WIPER*
* AVAILABLE ONLY WITH THE WIPER MODELS.