Pelco Manual C2434M (7/01) 15
GENERAL
Environment
In-Ceiling: Indoor only
Pendant: Indoor/outdoor
Operating Range
In-Ceiling: 32 to 122°F (0 to 50°C)
Pendant: (Assumes no wind chill factor; for detailed test conditions,
contact Pelco)
Maximum: 140°F (60°C) absolute maximum
122°F (50°C) sustained maximum
Minimum -15°F (-9.4°C) absolute minimum
Dimensions: See Figure 1
Weight Unit
Back Box and Lower Dome
In-ceiling: 3 lb (1.36kg)
Pendant: 7 lb (3.17 kg)
Dome Drive: 2.65 lb (1.20 kg)

(Design and product specifications subject to change without notice.)

6.8
(17.27)
10.25
(26.03)
10.37
(33.95)
fl6.13
(fl15.57)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES
Figure 1. Dimension Diagram