1.Locate the center point of the mounting location and insert the compass tool. Draw a circle.

2.Cut the circle out of the ceiling.

3.Use the mounting ring as a template and mark the screw hole pattern onto the mounting surface. Prepare the holes.

4.Install the mounting plates. Use the eight 10-32 x 3-inch screws (supplied) and install the mounting ring (A) and two back mounting plates (B).

a.Line up the mounting ring with the eight fastener holes.

b.Feed one back mounting plate (B) through the hole in the ceiling (C) and line up with four fastener holes.

c.Install fasteners through the mounting ring (A), ceiling, and out the back mounting plate (B).

d.Install second back mounting plate (B).

5.Attach the conduit fitting, lock nut, and safety chain bracket. Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg).

6.Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open.

Pull wiring into the back box through the conduit fitting. Refer to Table A, Table B, and Table C for wiring distances.

Table A. Video Coaxial Cable Requirements

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

 

 

RG6/U

1,000 ft (305 m)

 

 

RG11/U

1,500 ft (457 m)

 

 

*Cable requirements: 75 ohms impedance

All-copper center conductor All-copper braided shield with 95% braid coverage

Table B. 24 VAC/24VDC Wiring Distances

The following are the recommended maximum distances for 24 VAC and 24 VDC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC- or DC-powered devices.)

AC/DC

 

Wire Gauge

 

Total VA/

20 AWG

18 AWG

16 AWG

14 AWG

Total Watts

(0.5 mm2)

(1.0 mm2)

(1.5 mm2)

(2.5 mm2)

23 VA/

123 ft

196 ft

311 ft

495 ft

15 watts

(38 m)

(60 m)

(95 m)

(151 m)

 

 

 

 

 

NOTE: Input power for the dome is 24 VAC or 24 VDC. Using 24 VAC input power, power consumption is 23 VA per dome. Using 24 VDC input power, power consumption is 0.7 A (15 watts). Use a 24 VAC transformer with a minimum of 40 VA per dome.

.

Table C. UTP Wiring Distances

Receiver

Maximum Distance

 

 

Active

0-3,000 ft

(Video Only)

(0-914.4 m)

 

 

Passive

0-750 ft

(Video, Coaxitron, Pelco V-Sync)

(0-228.6 m)

 

 

NOTE: As a minimum, UTP requires Cat5, 100-ohm twisted pair cable.

C3419M-B (11/06)

3

Page 3
Image 3
Pelco C3419M-B manual Ac/Dc