8C3419M-B (11/06)
Switch Settings
WARNING: If you are using D-type or P-type control, your syste m may not operate if the baud rate and address
switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and
address 1).
Table E. Switch Settings for SW2
Special Systems
Switch Number 12345678910
AD-32 Preset System ON
CM9502 Setting ON
Vicon Not currently available; SW2-3 is reserved for future use.
Serial Port Settings
Switch Number 12345678910
RS422 OFF OFF
RS485, Four Wire OFF ON
RS485, Two Wire ON ON
D or P Protocol Baud Rate
Switch Number 12345678910
2400 Baud (Default for D-type Control) OFF OFF OFF
4800 Baud (Default for P-type Control) ON OFF OFF
9600 Baud OFF ON OFF
Video Cable Type
Switch Number 12345678910
Coax Cable OFF
UTP Cable ON
Dome Termination
Switch Number 12345678910
Termi nate d ON
Not Terminated OFF