Pelco Manual C543M-A (7/03) 19

1234

S2

DIP switch 2 has the following functions:

Table B. Output Card S2 Functions

S02
Description 1234
2400 Baud OFF OFF
4800 Baud OFF ON
9600 Baud ON OFF
19.2 K Baud ON ON
NTSC* OFF
PAL* ON
Default setting OFF
Must be ON for VIDEO LOSS
feature to operate ON
*X55 jumpers (refer to Table C) need to be set per Table C.
Setting the Jumpers on the Video Output Card
There are two jumper locations on the Video Output Card (refer to Figure 12 inset).
JP2 and X55. JP2 is used to control the program loading sequence and must always
have a jumper installed for proper operation. X55 is an eight-position header used
to set the standard required for video black generator operation. Refer to Table C
for a complete list of the available standards and the jumper location.
JP2 is a two-pin header used to control the program loading sequence and
must always have a jumper installed for proper operation.
X55 is an eight-pin header used to set the video standard for the video black
generator.

Table C. X55 Jumper Definitions

STANDARD OSC. FREQ. 1-2 3-4 5-6 7-8
SECAM1 5.0 MHz ON ON ON ON
SECAM2 5.0 MHz ON ON OFF ON
624 5.0 MHz ON OFF ON ON
PAL/CCIR 5.0 Mhz ON OFF OFF ON
NTSC1 5.034964 MHz ON ON ON OFF
NTSC2 5.034964 MHz ON ON OFF OFF
524 5.034964 MHz ON OFF ON OFF
PAL-M 5.034964 MHz ON OFF OFF OFF