6C685M-D (2/03)
MOUNTING
CAUTION: The recorder should be installed in an air conditioned room where the temperature is maintained between 65° and
70°F (18° and 21°C) with relative humidity not to exceed 80 percent, non-condensing.
The recorder should be connected to an uninterruptible power supply (UPS) capable of supplying 2A for 120 VAC power systems
or 1A for 230 VAC power systems.
Each recorder has been pre-configured to work with specific storage units. Each storage unit must be connected to the proper port
on the recorder. There is a label in the upper left corner on the back of the recorder (above the fan) that identifies the recorder. For
example, “Pelco 1” may appear on the label. The SCSI connectors on the back of the recorder are labeled with numbers from 0-3
that identify where to connect “Pelco 1” storage units. If the system is not connected correctly, it will malfunction.
The recorder can be placed on a flat surface, such as a shelf, or it can be installed in a 19-inch (48.26 cm) equipment rack.
NOTE: Allow one rack unit (1.75 inches or 4.5 cm) of space above the recorder for air circulation.
To install the recorder in an equipment rack:
1. Attach the two brackets to each side of the recorder.
2. Attach the support rails to the equipment rack.
3. Place the recorder onto the support rails. It should easily slide in and out of the rack.
4. Fasten the rack ears to the equipment rack.
Figure 2. Installation of Support Rails