Table A. Video Coaxial Cable Wiring Distances

EXAMPLE: An enclosure that requires 80 vA and is installed 35 feet (10 m) from the trans- former would require a minimum wire gauge of 20 AWG.

NOTE: Distances are calculated in feet; values in parentheses are meters.

9.Adjust the glands for a tight fit around the cables.

10.Adjust the camera focus and iris if necessary. If you need to adjust the focus and iris manu- ally, remove the front cover, adjust the focus and iris, and replace the front cover.

11.Adjust the pan and tilt of the mount, if applicable.

Table A. Video Coaxial Cable Wiring Distances

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

RG6/U

1,000 ft (305 m)

RG11/U

1,500 ft (457 m)

 

 

*Minimum cable requirements: 75 ohms impedance All-copper center conductor

All-copper braided shield with 95% braid coverage

Table B. 24 VAC Wiring Distances

The following are the recommended maximum distances for 24 VAC applications and are calcu- lated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

Wire Gauge

 

 

20

18

16

14

12

10

 

 

10

283

(86)

451 (137)

716 (218)

1,142 (348)

1,811 (551)

2,880 (877)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

141

(42)

225

(68)

358

(109)

571 (174)

905 (275)

1,440 (438)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

94 (28)

150

(45)

238 (72)

380

(115)

603

(183)

960 (292)

load

 

 

 

 

 

 

 

 

 

 

 

40

70 (21)

112

(34)

179 (54)

285 (86)

452

(137)

720 (219)

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

50

56 (17)

90 (27)

143 (43)

228 (69)

362

(110)

576 (175)

 

transformerfromdistance

consumedvATotal

 

 

 

 

 

 

 

 

 

 

 

 

60

47 (14)

75 (22)

119 (36)

190 (57)

301 (91)

480 (146)

 

 

 

 

 

 

 

 

 

 

 

 

70

40 (12)

64 (19)

102 (31)

163 (49)

258 (78)

411 (125)

 

 

 

 

 

 

 

 

 

 

 

 

80

35 (10)

56 (17)

89

(27)

142 (43)

226 (68)

360 (109)

 

 

 

 

 

 

 

 

 

 

 

 

 

90

31

(9)

50 (15)

79

(24)

126 (38)

201 (61)

320 (97)

 

 

 

 

 

 

 

 

 

 

 

 

 

100

28

(8)

45 (13)

71

(21)

114 (34)

181 (55)

288 (87)

 

 

 

 

 

 

 

 

 

 

 

 

 

110

25

(7)

41 (12)

65

(19)

103 (31)

164 (49)

261 (79)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

23

(7)

37 (11)

59

(17)

95

(28)

150 (45)

240 (73)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

130

21

(6)

34 (10)

55

(16)

87

(26)

139 (42)

221 (67)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140

20

(6)

32

(9)

51

(15)

81

(24)

129 (39)

205 (62)

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

170

16

(4)

26

(7)

42

(12)

67

(20)

106 (32)

169 (51)

 

150

18

(5)

30

(9)

47

(14)

76

(23)

120 (36)

192 (58)

 

 

160

17

(5)

28

(8)

44

(13)

71

(21)

113 (34)

180 (54)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

15

(4)

25

(7)

39

(11)

63

(19)

100 (30)

160 (48)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

190

14

(4)

23

(7)

37

(11)

60

(18)

95

(28)

151 (46)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

14

(4)

22

(6)

35

(10)

57

(17)

90

(27)

144 (43)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAINTENANCE

Regularly scheduled maintenance prolongs the operational life and appearance of the equipment.

Clean the window regularly with a mild, nonabrasive detergent in water and a soft cloth to main- tain picture clarity.

Service Manual

If you need to repair the camera enclosure, obtain a service manual in one of the following ways:

Go to Pelco’s web site at ftp://www.pelco.com and find service manual C413SM.