10 C1506M-A (8/02)

FUSE REPLACEMENT

CAUTION:
These service instructions are for use by qualified service personnel only. To
reduce the risk of electrical shock, do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.
IRD2024
Lens/Auxiliary Fuse
A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check
the fuse.
ERD2200
Main Fuse
The main fuse protects the pan/tilt output when 24 VAC pan/tilt operation is selected. It also
protects the 24 VAC camera output. Refer to the
ERD2200 Wiring
section for fuse location and
values.
Enclosure Fuse
The enclosure fuse protects the pan/tilt output when 115/230 VAC pan/tilt operation is selected. It
also protects the enclosure output. Refer to the
ERD2200 Wiring
section for fuse location and
values.
Lens/Auxiliary Fuse
A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver inside the
housing to check the fuse.