6C1506M-A (8/02)

ERD2200 WIRING

ENCLOSURE
POWER OUT
LL
NN
GROUND
STUD
POWER
TERMINALS
MAIN
POWER IN
Figure 2. ERD2200 Receiver Figure 3. ERD2200 Power Connections
1. Fuses are installed for 115 VAC operation. For 230
VAC operation, install the appropriate fuses
(supplied). Refer to Figure 2.
2. Set the power selector switch to either 115V or
230V to match your input power. Refer to Figure 2.
3. Loosen the thumbscrew and lift out the door protecting the power terminals (refer to Figure 2).
4. Connect main power.
The bottom of the housing has five conduit entries (fittings not supplied) to bring wiring into
the receiver. Connect 115/230 VAC to the Main Power In terminals inside the receiver (refer to
Figure 3) with AC high going to the L (line) terminal and AC low to the N (neutral) terminal.
Connect ground wire to the stud inside the housing. Do not turn on power.
5. Connect enclosure power (optional).
If you have an enclosure with heater, blower, or defroster, connect wires from the pan/tilt or
enclosure to the Enclosure Power Out terminals inside the receiver (refer to Figure 3). The
enclosure must use the same power as the receiver.
Refer to Figure 4 for steps 6-12.
6. Connect the camera power.
If your camera uses 24 VAC, connect the camera to the CAM PWR connector on the front of the
receiver. The camera’s power must not exceed 5 VA.
If your camera uses 115 or 230 VAC, connect the camera’s power leads to the Enclosure Power
Out terminals inside the receiver. The camera’s power must be the same as the receiver’s
power (Main Power In terminals).
7. Replace the door over the power terminals.
Input Power Enclosure Main
115 VAC 4A .5A
230 VAC 2A .25A
MAIN FUSE
POWER
TERMINALS
(INSIDE)
ENCLOSURE
FUSE
POWER
SELECTOR
SWITCH
P/T GROUND
STUD