16 C311M-L (1/05)
PROGRAMMING – ES30PC16/ES31PC16
Backlight comp Off
Zoom limit x- -
Reset camera
<Gain/AGC>
<Auto iris>
Next
Exit
Camera Menu
Line Sync On
Line Sync Phase 0
Exit
Line Sync Menu
Power Up Default
Exit
Power-Up Menu
Wiper Mode Momentary
Wiper Dwell <s> 2
Wiper Time <m> 60
Exit
*Wiper Menu
Limit Stops Off
Set Man Limits
Clear Man Limits
Set Scan Limits
Clear Scan Limits
Exit
Limit Stop Menu
Repeat Constant
Disp Pos Top Right
ACK Act Always On
<Current Reading>
Alert Reset
Exit
Alert Menu
Gain Limit 27
Exit
Gain/AGC Menu
Auto-iris mode Auto
Auto-iris level 66
Auto-iris peak 8
Exit
Auto Iris Menu
Shutter speed Auto
Auto focus mode Auto
<Sharpness>
<White balance>
Prev
Exit
Next Menu
<Camera>
<Line Sync>
<Power Up>
*<Wiper>
<Limit Stop>
<Alert>
<Other>
ACK Alert
Exit
MAIN MENU
Auto Sharpness On
Sharpness - -
Exit
Sharpness Menu
Auto white bal On
R-Gain 182
B-Gain 182
Exit
White Balance Menu
PRESETS
The following presets are
reserved for special functions.
Preset Function
1 Park
33 Flip command
34 Pan zero command
90-91 Manual limit stops
92-93 Auto limit stops
95 Select camera
programming menu
96 Stop a scan
97 Random scanning
98 Frame scanning
99 Auto scanning
*ES31PC only
1. Access main menu (preset 95).
2. Make main menu selections.
Joystick: Move up or down to position cursor or
to toggle between selections.
Iris Open: Enter.
Iris Close: Cancel.
NOTE: For American Dynamics
controllers with only 32 presets,
set switch SW1-5 on the Esprit
system to the ON position. When
SW1-5 is ON, preset
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
94 becomes 27
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
89 becomes 22
88 becomes 21
If the limit stops are turned off
(refer to the Limit Stops section),
presets 23-26 can be used as
regular presets. For detailed instructions,
refer to the following sections.
Menu items are listed alphabetically.
Proportional pan On
Park time minutes 0
Scan Speed deg/s 25
Pattern Length 1.5 min
Spd Profile 50 MPH Wind
<Zone Blank>
<Az/El/Direction>
Exit
Other Menu
Temperature 37 C
98 F
Dewpoint 08 C
46 F
Pressure 10.30 psig
0.71 bar
Refresh
Exit
IOC Internal Reading Video Blank Zone 1 Off
2 Off
3 Off
4 Off
5 Off
6 Off
7 Off
8 Off
Exit
Zone Blank Menu
Set Azimuth Zero 0
Az/El Left
Az/El Line 10
Direction Right
Direction Line 10
Zoom Center
Zoom Line 10
Disp Duration 2
Exit
Az/El/Direction