Model Number Imput Voltage Power Consumption Cable Size Cable Distance
BK700/200 230 VAC 9 watts 20 AWG 25,609 feet (7,805 m)
18 AWG 40,495 feet (12,342 m)
16 AWG 64,328 feet (19,606 m)
14 AWG 102,239 feet (31,161 m)
HK706-1 120 VAC 80 watts 20 AWG 533 feet (162 m)
18 AWG 857 feet (261 m)
16 AWG 1,355 feet (413 m)
14 AWG 2,153 feet (656 m)
HK706-2 24 VAC 80 watts 20 AWG 34 feet (10 m)
18 AWG 54 feet (17 m)
16 AWG 86 feet (26 m)
14 AWG 137 feet (42 m)
HK706-3 230 VAC 80 watts 20 AWG 2,881 feet (878 m)
18 AWG 4,556 feet (1,389 m)
16 AWG 7,237 feet (2,206 m)
14 AWG 11,502 feet (3,506 m)
HK708/10-1 120 VAC 107 watts 22 AWG 398 feet (121 m)
20 AWG 641 feet (195 m)
18 AWG 1,013 feet (3092 m)
16 AWG 1,6102 feet (491 m)
HK708/10-2 24 VAC 66 watts 20 AWG 42 feet (13 m)
18 AWG 66 feet (20 m)
16 AWG 104 feet (32 m)
14 AWG 166 feet (51 m)
HK708/10-3 230 VAC 84 watts 20 AWG 2,744 feet (836 m)
18 AWG 4,399 feet (1,322 m)
16 AWG 6,8928 feet (2,101 m)
14 AWG 10,954 feet (3,339 m)
Combination of 120 VAC 84 watts 22 AWG 507 feet (155 m)
BK700 & 20 AWG 816 feet (249 m)
HK706-1 18 AWG 1,291 feet (393 m)
16 AWG 2,051 feet (625 m)
Combination of 24 VAC 83 watts 20 AWG 33 feet (10 m)
BK700-24 & 18 AWG 52 feet (16 m)
HK706-2 16 AWG 83 feet (25 m)
14 AWG 132 feet (40 m)
Combination of 230 VAC 89 watts 20 AWG 2,590 feet (789 m)
BK700/220 & 18 AWG 4,095 feet (1,248 m)
HK706-3 16 AWG 6,505 feet (1,983 m)
14 AWG 10,339 feet (3,151 m)
Combination of 120 VAC 111 watts 22 AWG 384 feet (117 m)
BK700 & 20 AWG 618 feet (188 m)
HK708/10-1 18 AWG 977 feet (298 m)
16 AWG 1,552 feet (473 m)
Combination of 24 VAC 69 watts 20 AWG 40 feet (12 m)
BK700/24 & 18 AWG 63 feet (19 m)
HK708/10-2 16 AWG 100 feet (30 m)
14 AWG 159 feet (48 m)
Combination of 230 VAC 93 watts 20 AWG 2,748 feet (755 m)
BK700/220 & 18 AWG 3,919 feet (1,194 m)
HK708/10-3 16 AWG 6,225 feet (1,897 m)
14 AWG 9,894 feet (3,016 m)

Blower Kit

If you are istalling the blower kit in conjunction with a heater kit, skip this section and refer to

Blower and Heater Kits (Dual Installation)

.
To install a blower kit, perform the following steps:
1. Attach the blower assembly onto the brackets at the rear of the camera sled using the
hardware provided (see Figure 1).
2. Wire as shown in Figure 2. Refer to Table A for recommended cable sizes.

Table A. Power Requirements and Recommended Cable Sizes (Continued)