Pelco installation manual ICS100 Installation ICS150 Installation

Models: ICS150

1 8
Download 8 pages 26.46 Kb
Page 5
Image 5
ICS100 Installation

ICS100 Installation

ICS150 Installation

￿Install the new board inside the back box.

Note: The BNC connector attached to the board is not required for the installation. Either push the video cable into the conduit or cut the cable and remove it. Cut the cable as close to the board as possible so that it will not interfere with the operation of the unit.

￿Connect the input power wires to the new board.

24 VAC: Connect the wires to the two blocks labeled 24.

12 VDC: Connect the wires to the blocks labeled 12 and GND. Move the jumper to the 12 VDC position.

￿Plug the block male connector attached to the new board into the female video connector of the old board. Connect power, video, and heater.

C2405M (8/02)