LOCATION AND FUNCTION OF PARTS

LOCATION AND FUNCTION OF PARTS

Refer to Figure 1.

￿Lens Mount

The camera has a standard CS lens mount but can use a C-mount lens when a C/CS-mount adapter is installed between the lens and camera.

￿Back Focus Lock Screw

Loosen to adjust the back focus to match the lens attached to the CS mount. Refer to the section on Back Focus Adjustment in this manual.

￿Camera Mounts

Top or bottom mounting. Maximum thread length is 3/16-inch. Attach the camera mount adapter to extend thread depth to a standard 1/4-inch.

￿Level Adjuster

Controls the video output level when using a DC-controlled auto iris lens.

￿Lens Connector

Four-pin auto iris drive connector.

￿Video Output Connector

This coaxial connector (BNC type) outputs the video signals.

￿Iris Mode Selector Switch

Switch to VIDEO when an auto iris lens is controlled by a video signal. Switch to DC when using a DC voltage drive lens.

￿LL ADJ Switches

Use switches to adjust the vertical phase up or down to eliminate vertical roll when multiple cameras are connected to a switching device. Each cameraÕs output is synchronized to the frequency of the power supply.

￿AGC – Automatic Gain Control

Automatically adjusts the image to compensate for changes in light levels. The AGC function switch can be turned ON/OFF by moving the AGC switch right or left. AGC is factory set to ON.

￿￿ESC – Electronic Sensitivity Control

This function changes the sensitivity of the camera by varying the electronic shutter speed according to the amount of incident light. The ESC range is 1:300. To reset the ESC function switch, move the ON/OFF switch right or left. The ESC is factory set to the ON position.

￿￿BLC – Backlight Compensation

The backlight compensation function allows fine picture correction to prevent the subject from being extremely dark due to strong backlight. The BLC function switch can be turned ON/OFF by moving the BLC switch right or left. The BLC is factory set to the OFF position. Set the AGC switch to ON when using the BLC function.