7.0 SPECIFICATIONSMECHANICAL
Pan: 0-355° movement in horizontal plane
Speed 6°/sec ±1° (No load condition)
Tilt: ±90° movement in vertical plane
Speed 3°/sec ± .5° (No load condition)
Torque 20 ft/lb with specified voltage
Maximum Load: 40 lb (18.16 kg) at 5 inches (12.7 cm) from tilt table surface to
center of gravity
Gearing: Adjustable worm-gear final drive to prevent drift and minimize
backlash
Bearings
Pan: Heavy-duty ball bearings
Tilt: Oilite bronze bushing
Braking: Dynamic for instantaneous stopping
ELECTRICAL
Input Voltage: 115 VDC required for pan/tilt
Power Requirements
Running:
Pan: .30 amp (34 vA)
Tilt: .30 amp (34 vA)
Starting:
Pan: .44 amp (51 vA)
Tilt: .44 amp (51 vA)
Connectors: AMP CPC type (mate supplied)
Motors: 115 VDC permanent magnet
Limit Switches
Pan: 5 amp
Tilt: 5 amp
External adjustment
Interference: Electrical filtering to minimize starting and stopping glitches
Conductor
Requirements: 6, unshielded (Functions: left, right, up, down, motor common,
safety ground)
(Variable speed, no additional conductors. For models with PP