14 Pelco Manual C650M (12/98)4.3 CONNECTING THE VCR TO A MULTIPLEXER
Figure 2 shows how to connect the VCR to an MX4000 Series Genex™ Multiplexer.
•For Automatic Speed Tracking (“B” lines in Figure 2)
This lets the VCR control the multiplexer’s recording speed. It is the most effi-
cient recording method.
1. Connect the VCR’s CLK output to the multiplexer’s head switching (HS)
input to synchronize camera switching.
2. Connect the multiplexer’s ground terminal to the VCR’s GND terminal.
•For Alarm Recording (“A” lines in Figure 2)
This is to start and stop recording when there are alarms.
1. Connect the multiplexer’s normally open (NO) relay terminal to the VCR’s
SET IN (alarm input) terminal.
2. Connect the common C terminal to the VCR’s GND terminal.
NOTE:
Cameras and monitors are
connected to the multiplexer. Fig-
ure 2 shows the connection be-
tween the VCR and an MX4000
Series Genex™ Multiplexer. Refer
to the multiplexer manual for addi-
tional component connections.
Figure 2. Connecting VCR to Multiplexer
VCR
AUX
MAIN
SPOT
SVHS
OUT IN
SVHS
IN COM OUT NN
H
OCCS
120 VAC 60 Hz
ALARMS
12 34 5 67 8 91011 1415161213
MX4000 GENEX™ SERIES MULTIPLEXER
TIME-LAPSE VCR
REMOTE
RESET
IN
GND CLK
AUDIO VIDEO
IN OUT
CALL
OUT
OUT
MIC
ALM
IN
RECSET RST MODE
A
B
COAXIAL CABLE