INTERIOR fINISHINg
If products cannot be nished immediately, cover with clear plastic to protect from dirt,
damage and moisture. Remove any construction residue before nishing. Sand all wood
surfaces lightly with 180 grit or ner sandpaper. DO NOT use steel wool. BE CAREFUL
NOT TO SCRATCH THE GLASS. Remove sanding dust.
Pella products must be nished per the below instructions; failure to follow these instructions
voids the Limited Warranty.
• On casement and awnings, it is optional to paint, stain or nish the vertical and horizontal
sash edges.
• On single-hung and double-hung, do not paint, stain or nish the vertical sash edges, any
nish on the vertical sash edges may cause the sash to stick; it is optional to paint, stain or
nish the horizontal sash edges.
• On patio doors, it is optional to paint, stain or nish the vertical and horizontal panel edges.
Note: To maintain proper prod uct performa nce do not paint, ni sh or remove the
weather-strip ping, mohair dust p ads, gaskets or v inyl parts. Air an d water leakage wi ll
result if these parts a re removed. Af ter nishing , allow venting wi ndows and doors to
dry completely bef ore closing them .
Pella Corporation is not responsible for interior paint and stain nish imperfections for
any product that is not factory-applied by Pella Corporation. Use of inappropriate nishes,
solvents, brickwash, or cleaning chemicals will cause adverse reactions with window and door
materials and voids Limited Warranty.
For additional information on nishing see the Pella Owner’s Manual or go to
www.pella.com.
EXTERIOR fINISHINg
e exterior frame and sash are protected by aluminum cladding with a Pella EnduraClad® or
EnduraClad Plus baked-on factory nish that needs no painting. Clean this surface with mild
soap and water. Stubborn stains and deposits may be removed with mineral spirits. DO NOT
use abrasives. DO NOT scrape or use tools that might damage the surface.
Use of inappropriate nishes, solvents, brickwash or cleaning chemicals will cause adverse
reactions with window and door materials and voids the Limited Warranty.
CARE AND mAINTENANCE
Care and maintenance information is available in the Pella Owner’s Manual. You can obtain
an owner’s manual by contacting your local Pella retailer. is information is also available at
www.pella.com.
Because all construction must anticipate some water inltration, it is important that the
wall system be designed and constructed to properly manage moisture. Pella Corporation
is not responsible for claims or damages caused by anticipated and unanticipated water
inltration; deciencies in building design, construction and maintenance; failure to install
Pella® products in accordance with Pella installation instructions; or the use of Pella products
in wall systems which do not allow for proper management of moisture within the wall
systems. e determination of the suitability of all building components, including the use
of Pella products, as well as the design and installation of ashing and sealing systems are the
responsibility of the Buyer or User, the architect, contractor, installer, or other construction
professional and are not the responsibility of Pella.
Pella products should not be used in barrier wall systems which do not allow for proper
management of moisture within the wall systems, such as barrier Exterior Insulation and
Finish Systems, (EIFS) (also known as synthetic stucco) or other non-water managed systems.
Except in the states of California, New Mexico, Arizona, Nevada, Utah, and Colorado, pella
makes no warranty of any kind and assumes no responsibility for pella windows and
doors installed in barrier wall systems. In the states listed above, the installation of pella
products in barrier wall or similar systems must be in accordance with pella installation
instructions.
Product modications that are not approved by Pella Corporation will void the Limited
Warranty.
ImPORTANT NOTICE
DOORS ALL DOORS ALL DOORS ALL DOORS ALL DOORS ALL DOORS ALL DOORS