OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Control Panel

Air Outlet

Base

C

D

A

B

LO HI FAN

OSC

 

+

 

 

 

TIMER

-

 

 

ON/OFF

Control Panel Functions

A

 

Digital Indicator

 

 

B

 

Timer Indicator Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

LO Power Indicator

 

D

 

HI Power Indicator

 

 

 

 

 

 

 

Light

 

 

 

 

 

 

 

 

IMPORTANT!

Your heater is equipped with a polarized alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your outlet. DO NOT defeat the safety purpose of the polarized plug.

Place the heater on a firm level surface free from obstructions, and at least 3 ft. away from any wall and any other objects such as furniture, curtains, plants or combustible material.

Plug the heater into a grounded 120V outlet. The buzzer will sound and the “ADigital Indicator will indicate the room temperature. When the heater is on, every time you press a key, the buzzer will sound.

Press the POWER key. The operating mode is switched circularly in sequence of HI -LO-FAN-OFF.

FAN: The Fan circulates room air only. The heating elements are “ OFF” .

LOW: The Fan and heating elements operate at 900 Watts.

HIGH: The Fan and heating elements operate at 1500 Watts.

Temperature setting: When the heater is on (HI or LO), press “ +” or -key and the Digital Indicator will indicate the last set temperature (75 oF is the ex-factory setting). You can now adjust your desired temperature by pressing “ +” or -key, the temperature range is 40-95 oF. If there is no operation in 5 seconds, the setting will be saved and the Digital Indicator will again display the room temperature. Once the temperature is set, the unit will select the operating mode based on the following 2 conditions of A and B:

A.If the setting temperature is higher than the room temperature, the heater continues heating until the room temperature reaches the setting temperature. Once the room temperature reaches your setting temperature, the heater will stop heating. The heater will resume heating when the room temperature is lower than the set temperature. The heater will cycle on and off this way to maintain the setting temperature.

B.If the setting temperature is lower than or equal to the room temperature, the temperature display will flash and the unit will stop heating. When the room temperature falls down to less than the setting temperature, the unit will resume heating. The heater will cycle on and off this way to maintain the setting temperature.

Note: Every time you turn on the heater, the heater will heat forcedly for 2 minutes. After that the heater will work based on the below instruction. And when the room temperature reaches the setting temperature or the setting temperature is lower or equal to the room temperature, the heating element will shut off immediately, but the fan motor will continue running for 30 seconds before shut off. This is a safety feature to protect the unit from being too hot.