IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety pre- cautions with this equipment, in- cluding the following.

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it can- not be readily disassembled for storage. A storable pool is con- structed so that it may be readily disassembled for storage and re- assembled to its original in- tegrity.

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL

INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your sys- tem or in this manual, look for one of the following signal words and be

alert to the potential for personal injury.

warns about hazards that will cause death, serious personal in- jury, or major property damage if ignored.

warns about hazards that can cause death, serious personal in- jury, or major property damage if ignored.

warns about hazards that will or can cause minor personal in- jury or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip- ment. Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing severe injury or property damage.

Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional per-

form all pressure tests.

1.Do not connect system to a high pressure or city water system.

2.Use equipment only in a pool or spa installation.

3.Trapped air in system can cause explosion. BE SURE all air is out of sys- tem before operating or testing equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before testing.

Release all air in system before testing.

Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.

Water pressure for test must be less than 25 PSI (172 kPa).

Water Temperature for test must be less than 100o F. (38o C).

Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.

NOTICE: These parameters apply to Sta-Rite equipment only. For non-Sta-Rite equipment, consult manufacturer.