Voltage:

Voltage:

Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.

Values given in tables below are for PUMP MOTOR ONLY. If addi-

Remote Switching For 2-Speed Pumps tional spa accessories are installed on pump motor circuit (heater, blower, etc.), include their amperage draw when figuring wire and circuit breaker sizes.

TABLE I - RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 Hz MOTORS

 

 

 

 

Branch

 

AWG (mm2) Wire Gauge Size

 

 

 

 

Full

Circuit

 

Dist in Ft. (M) - Service to Motor

 

Model

Motor

 

Load

Breaker

0-100

101-200

201-300

Temp

No.

HP

Volts

Amps

Amp Rating

(0-30)

(31-60)

(61-90)

Deg. C.

 

 

 

 

 

 

 

 

 

Single Speed Pumps:

 

 

 

 

 

 

 

 

JSACL-A

1/2

115

7.0

15

14

(2.0)

12 (3.0)

10 (5.5)

75

JSADL-2A

3/4

115

9.0

15

14

(2.0)

14 (2.0)

10 (5.5)

75

JSAEL-2A

1

115

12.0

15

14

(2.0)

10 (5.5)

8 (8.4)

75

 

 

 

 

 

 

 

 

 

JSAFL-A

1-1/2

115/230

16.4/8.2

25/15

10/14 (5.5/2.0)

8/14 (8.4/2.0)

6/12 (14/3.0)

75

JSAEFL-A

1-1/2

115/230

14.4/7.2

20/15

12/14 (3.02.0)

8/14 (8.4/2.0)

6/14 (14/2.0)

75

 

 

 

 

 

 

 

 

 

JSADL-230A

3/4

230

4.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAEL-230A

1

230

6.1

15

14 (2.0)

14 (2.0)

14 (2.0)

75

 

 

 

 

 

 

 

 

 

Two Speed Pumps:

 

 

 

 

 

 

 

 

JSAYDL-A

3/4-1/8

115

9.0/2.7

15

14 (2.0)

12 (3.0)

10 (5.5)

75

JSAYDL-LA

3/4-1/8

115

9.0/2.7

15

14 (2.0)

12 (3.0)

10 (5.5)

75

JSAYEL-A

1-1/6

115

11.7/3.4

15

14 (2.0)

10 (5.5)

8 (8.4)

75

JSAYEL-LA

1-1/6

115

12.0/3.3

15

14 (2.0)

10 (5.5)

8 (8.4)

75

JSAYFL-LA

11¼2 - 1/6 115

16.6/3.6

25

10 (5.5)

8 (8.4)

6 (14)

75

 

 

 

 

 

 

 

 

 

JSAYDL-230A

3/4-1/8

230

4.7/1.4

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYEL-230A

1-1/6

230

6.3/1.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYFL-230A

11¼2 - 1/6 230

8.1/1.7

15

14 (2.0)

14 (2.0)

12 (3.0)

75

 

 

 

 

 

 

 

 

 

JSAYDL-220A

3/4-1/8

220

5.4/1.4

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYEL-220A

1-1/6

220

6.3/1.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

 

 

 

 

 

 

 

 

 

 

Remote Switching For 2-Speed Pumps

Ground (Green)

L2

Common

 

 

 

 

 

B

 

 

 

A

Lo

Lo

 

 

 

 

L1

Hi

Hi

 

 

 

Circuit

 

Timer Motor

Remote

 

SPDT

Protector

 

Supply

 

 

 

Switch

Timer (optional)

Low Speed Only

Minimum switch and timer amp rating must equal Branch Fuse Rating given in "Recommended Circuit Breaker Size and Wiring Data" table.