Water Velocity
The maximum water velocity through the suction fitting or cover for any suction outlet must not exceed 1.5 feet per second unless the outlet complies with the latest ANSI/ASME Specification for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications. In any case, do not exceed the suction fit- ting’s maximum designed flow rate.
If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suction hydraulic system must be six feet per second or less even if one main drain (suction outlet) is completely blocked. The flow through the remaining main drain(s) must com- ply with the latest ANSI/ASME Specification for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications.
Testing and Certification
Suction outlet covers must have been tested by a nation- ally recognized testing laboratory and found to comply with the latest ANSI/ASME Specifications for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications.
Fittings:
ELECTRICAL
Ground motor before
connecting to electrical power supply. Failure to ground motor can cause se- vere or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock,
turn OFF power to motor be- fore working on electrical connections.
Ground Fault Circuit
Interrupter (GFCI) trip- ping indicates an electrical problem. If GFCI trips and will not reset, have a qualified
electrician inspect and repair electrical system.
Exactly match supply voltage to nameplate voltage. Incorrect voltage can cause fire or seriously dam-
age motor and voids warranty. If in doubt consult a li- censed electrician.
Fittings restrict flow; for best efficiency use fewest possi- | Voltage | ||||
ble fittings (but at least two suction outlets). | Voltage at motor must be not more than 10% above or | ||||
Avoid fittings which could cause an air trap. | below motor nameplate rated voltage or motor may over- | ||||
heat, causing overload tripping and reduced component | |||||
Pool fittings must conform to International Association of | |||||
life. If voltage is less than 90% or more than 110% of | |||||
Plumbing and Mechanical Officials (IAPMO) standards. | |||||
rated voltage when motor is running at full load, consult | |||||
Use only | power company. | ||||
|
| At Least |
|
| |
|
| 3 Feet |
|
|
IAPMO Certified |
| IAPMO Certified |
| ||
Cover or Suction Fitting, |
| Cover or Suction Fitting, |
No valves between | ||
Main Drain Sump | Tee and Main Drains | Main Drain Sump |
Suction Outlet
(Main Drain)
Valves OK between pump and Tee
Suction Outlet
(Main Drain)
Pump
2762 0197
Figure 3 – Recommended pump suction layout.
6