F. Hooking up the Legend® Platinum II

1.Remove the Pressure Tester from the free end of the Feeder Hose by unscrewing the Hose Nut. Left hand thread (reverse), (see illustration, previous page).

2.Place mender nut on Legend® Platinum II Swivel Mast. Connect the open end of the Feed Hose to the top of the Legend® Platinum II Swivel Mast and secure with the mender nut. The arch of the Feed Hose should align in the same direction as the Swivel Mast, there should be no twist in the Feed Hose after connection. (See illustration below.)

4.Gently place the Legend® Platinum II in the pool. Turn on the pool filtration pump.

5.Check to make sure the wheel RPM is between 25-32. See page 5 for instructions on wheel RPM.

G. Checking Operation

When operating correctly, the Legend® Platinum II will travel in a random pattern throughout the pool, vacuuming and sweeping the bottom. The climbing ability of the Legend® Platinum II is dependent on the pools structure and water flow coming into the pool. It will perform more efficiently in pools without sharp angles or curves in the transition from the floor of the pool to the wall.

FEED MAST

SWIVEL

HEAD FLOAT

FEED

HOSE

MENDER

NUT

THRUST

JET

The Legend® Platinum II comes with a Twist Lock Pressure Relief Valve (Wall Fitting). If the Legend® Platinum II is receiving too much water pressure, the Pressure Relief Valve in the Wall Fitting will release the excess water pressure.

Approximately every three minutes and 30 seconds the Legend® Platinum II will go into a back-up mode. The Back-Up Valve cycle time, while in the back-up mode, is approximately 30 seconds, pulling the Legend® Platinum II from problem areas.

3.Carefully twist lock the Sand & Silt debris bag onto the top of the Legend® Platinum II Vacuum Tube. Make sure there is a Rubber Debris Valve attached to the top of the Vacuum Tube before locking on the Sand & Silt bag, (this valve is similar to a check valve to help keep debris inside the bag when the water pressure is off).

The Sweep Hose operates in a gentle sweeping motion to prevent debris from becoming trapped in hard to reach corners of the pools.

If the Legend® Platinum II does not travel to all areas of the pool, turn off the pool filtration pump and make the necessary adjustments from the instructions on the next page.

4

LEGEND® PLATINUM II INSTALLATION MANUAL • MANUEL D’INSTALLATION LEGEND® PLATINUM II

Page 8
Image 8
Pentair Platinum II installation manual Hooking up the Legend Platinum, Checking Operation