1.Clean filter elements first according to cleaning procedure above.

2.Use one of the commercial filter cleaners listed (see Table III)

TABLE III - Specialty Filter Cleaners

(for Degreasing and Scale Removal)

Filter CleanseTM

Filter KleenTM

KleenItTM or

.

Strip Kwik®

 

Filter Cleanse™ is a trademark of Advantis Technologies, Inc., Filter Kleen™ is a trademark of Haviland Consumer Products, Inc., Strip-Kwik®and KleenIt® are trademarks and/or registered trade- marks of Bio-Lab, Inc..

Risk of fire or explosion. Isolate filter from system before chemical cleaning; rinse filter and ele- ments completely before returning to service. If filter cannot be isolated, remove media and clean at another location. Follow chemical manufacturer’s instructions for use. Do not mix chemicals except as directed by manu- facturer. Do not allow cleaning chemicals to mix or to come in contact with chlorines, bromines, other chemi- cals, or chemical feed devices.

3.Sponge or spray elements according to chemical manufacturer’s directions. Leave elements in operat- ing position or remove and clean elsewhere, de- pending on filter location, chemicals used, and chemical manufacturers instructions (see warning above).

4.If soaking is required, remove elements from filter body and submerge in a separate tank. Follow cleaner manufacturer’s instructions to mix enough chemical cleaner to soak element. Soaking may require four to six hours or more.

5.After soaking, drain and rinse elements com- pletely. Dispose of cleaners in accordance with codes and waste disposal ordinances.

6.Rinse inside of filter tank completely and re-install elements (have two people lifting - lift with care).

7.Follow instructions under “Assembly”, Page 5.

8.Restore valving and other plumbing to service po- sition; return system to service (see “Initial Startup”, Page 5).

SYSTEM INSPECTION

General

Wash outside of filter with a mild detergent and water. Rinse off with hose.

NOTICE: DO NOT use solvents to clean filter; solvents may damage plastic components in system.

NOTICE: Open air bleed valve and bleed all air from fil- ter each time pump is stopped and restarted.

Weekly Inspection:

1.Skimmer basket - remove debris.

2.Stop pump, release all pressure. Remove trap cover and basket, remove debris.

3.Bleed air from filter each time system is started.

4.Check pump for leaks. If found, see pump owner’s manual.

5.Check pump strainer lid for tightness. Do not over- tighten!

NOTICE: Filter must be protected from the weather and drained if freezing is anticipated. Allowing filter to freeze can cause damage to filter and WILL VOID THE WARRANTY!

Winterizing

1.Stop pump.

2.Open air release valve.

3.Remove both drain plugs from lower tank half; loosen union connection to inlet and outlet ports to allow in- ternal piping to drain. Leave unions loose over win- ter.

4.Drain ALL piping to and from filter.

5.Disassemble filter.

To avoid severe injury or major prop- erty damage, exactly follow instruc- tions under “Disassembly” (Page 5)!

6.Remove filter elements and store in a warm, dry area.

Do not remove or damage safety and instruction labels during cleaning. Replace any de- cals which may have been damaged.

7

Page 7
Image 7
Pentair S8M600 owner manual System Inspection, General, Weekly Inspection, Winterizing

S8M600 specifications

The Pentair S8M600 is a high-performance water treatment system designed to provide exceptional filtration and purification capabilities, making it an ideal choice for diverse applications, including residential, commercial, and industrial use. This unit has garnered attention due to its advanced features, robust design, and cutting-edge technologies that ensure efficient water management and sustainability.

One of the standout features of the S8M600 is its innovative multi-stage filtration process. This system employs multiple filtration layers, including pre-filters, activated carbon, and sediment filters, ensuring that contaminants such as chlorine, sediment, and other impurities are effectively removed. This thorough filtration process results in purified water free from odors and unpleasant tastes, enhancing the overall quality of water for various uses.

Another significant characteristic of the Pentair S8M600 is its user-friendly interface. The system is equipped with a digital display and intuitive controls, allowing users to monitor water quality and filtration performance easily. This feature not only improves user experience but also facilitates timely maintenance and troubleshooting, ensuring the system operates at peak efficiency.

Energy efficiency is another noteworthy aspect of the S8M600 design. The unit incorporates energy-saving technologies that minimize power consumption while maximizing filtration efficiency. This focus on sustainability makes the S8M600 an environmentally friendly choice, appealing to users who value both performance and ecological responsibility.

Moreover, the S8M600 is built with durable materials that ensure longevity and reliability. Its robust housing protects the internal components from damage while seamlessly blending into various settings. The system is also designed for easy maintenance, with replaceable filter cartridges that simplify the process of keeping the unit in optimal condition.

In summary, the Pentair S8M600 is a comprehensive water treatment solution that combines advanced filtration technology, user-friendly features, energy efficiency, and robust construction. Its ability to deliver high-quality purified water makes it a sought-after choice for anyone looking to improve water quality in their home or business. Whether for drinking, cooking, or industrial applications, the S8M600 stands out as a reliable and effective water treatment system.