Installation – Beer Pump Panels

Installation – Beer Pump Panels

Use panel as a template to mark where holes should be drilled on cooler wall.

(Note: Make sure panel is level and pumps are in the vertical position).

Drill 9/64” pilot holes in cooler wall. Use fasteners provided in installation kit to mount the beer pump panel to the cooler wall.

Push CO2 supply line over Keg Pressure Supply barbed inlet. (See diagram on page 3). Position clamp over joint and tighten. (Note: A safety Relief Valve should be installed between supply tank and shut-off point on carbon dioxide supply line. Relief setting depends on maximum system pressures).

Push air or CO2 supply line over Beer Pump Pressure barbed inlet. (See diagram on page 3). Position clamp over joint and tighten. If using compressed air, make sure air supply is clean and dry. Air must have a pressure dew point of 30°F. or lower to ensure pumps operate properly.

CAUTION: IF USING CO2 AS A

PRESSURE SUPPLY FOR PUMPS,

PUMP EXHAUST MUST BE VENTED

TO A WELL VENTILATED AREA TO

AVOID POSSIBLE ASPHYXIATION.

Push beer line (from trunk housing) over barbed Liquid outlet on flow reversal valve.

(see diagram on page 3). Position clamp over joint and tighten.

Push connector hose over Liquid inlet on beer pump inlet fitting. (See diagram on page 3). Position clamp over joint and tighten. (Note: Connector hose should not exceed 10 feet in length).

Install washer into hex nut on opposite end of connector hose. Connect to top threaded fitting of Perlick Smart Coupler.

Cut a piece of CO2 tubing and push one end onto barbed CO2 outlet. (See diagram on page3). Position clamp over joint and tighten. Push the other end over the barbed gas inlet on the Perlick Smart Coupler. Position clamp over joint and tighten.