Perlick CS1DPSP Parts List, Tools Required, Plumbing, Electrical, Uncrating and Inspection

Models: CS1DPSP

1 6
Download 6 pages 14.45 Kb
Page 3
Image 3
Parts List

Preparing the Cabinet for Use – Single Door Back Bar Cooler

Parts List

(2) Shelves.

Mini-Flourescent Light.

Shelf Clips.

Tools Required

#2 Phillips Screwdriver.

10” Crescent Wrench.

9/ 16” Allen Wrench.

3/ 8” Nut driver.

power Drill or Driver (for Leg Installation).

Plumbing

Features a floor drain with a 34” female pipe thread connection for disposal of condensate. Remove bottom or side drain plug with Allen wrench and attach 34” male pipe to external drain.

Electrical

The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.

Uncrating and Inspection

Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is

not responsible for damage in transit.

Installing Casters (Optional)

Attach four casters to the cabinet bottom; rigid cast- ers at the rear and swivel casters on the front. Use the supplied 1/ 4”- 20 x 3/ 4” hex head self-tapping machine screws.

Placing the Cabinet

Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit. A minimum of 2” clearance is required from back.

Leveling the Cabinet

When the cabinet is in place, check installation with carpenter’s level. When perfectly level, accumulated water will drain out. A slight pitch to the drain side will not harm the cabinet. Water may accumulate if cabinet is pitched to the opposite side.

Installing Base Plate (Optional)

Attach brackets to cabinet bottom in holes provided. Use #10 self-drilling hex sheetmetal screws. (See separate instructions, provided with kit). When returning cabinet to upright position, be careful not to bend brackets.

WARNING!

To avoid compressor damage,after returning cabinet to an upright position, let unit stand for

24 hours before plugging it in and running the unit.