Preparing the Cabinet for Use – Single Door Back Bar Cooler
Parts List
■(2) Shelves.
■
■Shelf Clips.
Tools Required
■#2 Phillips Screwdriver.
■10” Crescent Wrench.
■9/ 16” Allen Wrench.
■3/ 8” Nut driver.
■power Drill or Driver (for Leg Installation).
Plumbing
Features a floor drain with a 3⁄4” female pipe thread connection for disposal of condensate. Remove bottom or side drain plug with Allen wrench and attach 3⁄4” male pipe to external drain.
Electrical
The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.
Uncrating and Inspection
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is
not responsible for damage in transit.
Installing Casters (Optional)
Attach four casters to the cabinet bottom; rigid cast- ers at the rear and swivel casters on the front. Use the supplied 1/ 4”- 20 x 3/ 4” hex head
Placing the Cabinet
Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit. A minimum of 2” clearance is required from back.
Leveling the Cabinet
When the cabinet is in place, check installation with carpenter’s level. When perfectly level, accumulated water will drain out. A slight pitch to the drain side will not harm the cabinet. Water may accumulate if cabinet is pitched to the opposite side.
Installing Base Plate (Optional)
Attach brackets to cabinet bottom in holes provided. Use #10
WARNING!
To avoid compressor damage,after returning cabinet to an upright position, let unit stand for
24 hours before plugging it in and running the unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
3 | Form No. Z2091A |
Rev. 08.03.04 |