General Information – Single Door Back Bar Cooler

General Information – Single Door Back Bar Cooler

Refrigeration and Temperature Control

The Back Bar cabinet is equipped with a heavy- duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser.

NOTE: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.

Adjusting the temperature

The temperature control is inside the cabinet on the right-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.

Colder Temperatures:

Turn the adjusting screw clockwise (to the right).

Warmer Temperatures:

Turn the adjusting screw counterclockwise (to the left).

In normal operation the condensing unit will run approximately 16 hours per day. The condenser fan motor turns off and on with the condensing unit. The evaporator fan motor runs continuously. The fan motors are lifetime lubricated and will require no oiling.

NOTE:

Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted.

Cleaning the Condenser

Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure effi- cient operation.

CAUTION: Do not bend the fins while brushing the front of the condenser.

Condenser

The condenser (located behind the back cover) should be inspected every 30 days and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condenser unit efficiency.

 

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.