Lincoln Electric SVM112-B service manual Installation, Technical Specifications Power Wave

Models: SVM112-B

1 293
Download 293 pages 59.16 Kb
Page 8
Image 8

Return to Section TOC

Return to Master TOC

A-2

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS - POWER WAVE 450

INPUT -THREE PHASE ONLY

Input Voltages:

200

230

400

460

575

Input Currents

 

 

 

 

 

@ 500A/40 VDC

87

76

44

38

32

@ 450A/38 VDC

75

65

38

32

28

 

 

 

 

 

 

RATED OUTPUT

Section TOC

Master TOC

Duty Cycle

60% Duty Cycle

100% Duty Cycle

Constant Open

Circuit Voltage

75 Volts

Amps

500

450

Continuous

Current Range

5-540 Amps

Volts at Rated Amperes

40VDC

38VDC

Process

Current Ranges

GMAW 50-540 Amps

FCAW 40-540 Amps

STICK 30-540 Amps

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

Pulse

Pulse

Pulse and Background

Pulse

Current Range

Voltage Range

Time Range

Frequency

 

 

 

 

5-750 Amps

5-55 Volts

100 Microsec - 3.3 Sec

0.15 - 1000 Hz

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

Type 75°C

Type 75°C

Type 75°C

Input

Duty

Input Ampere

Copper Wire in

Ground Wire in

(Super Lag)

Voltage/

Cycle

Rating on

Conduit

Conduit

or Breaker

Freqency

 

Nameplate

AWG[IEC]

AWG[IEC]

Size (Amps)

 

 

 

Sizes (MM2)

Sizes (MM2)

 

200/50-60

60%

87

4

(25)

8

(10)

120

230/50-60

60%

76

4

(25)

8

(10)

100

400/50-60

60%

44

8

(10)

10

(6)

50

460/50-60

60%

38

8

(10)

10

(6)

50

575/50-60

60%

32

8

(10)

10

(6)

50

200/50-60

100%

75

4 (25)

8

(10)

100

230/50-60

100%

65

4

(25)

8

(10)

100

400/50-60

100%

38

8

(10)

10

(6)

50

460/50-60

100%

32

8

(10)

10

(6)

50

575/50-60

100%

28

8

(10)

10

(6)

40

 

 

 

 

 

 

 

 

PHYSICAL DIMENSION

Height

Width

 

Depth

Weight

 

905 mm

515 mm

 

1010 mm

137.9 kg

35.6 in.

20.3 in.

 

39.8 in.

303.5 lbs.

 

 

 

 

 

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C

 

 

POWER WAVE 450

Page 8
Image 8
Lincoln Electric SVM112-B service manual Installation, Technical Specifications Power Wave