F-5

F-5

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Major physical or electrical dam-

1.

Contact your local authorized

 

 

age is evident when the sheet

 

Lincoln Electric Field Service

 

 

metal cover(s) are removed.

 

Facility for technical assis-

 

 

 

 

tance.

 

 

 

 

 

 

 

Machine is dead – no output – no

1.

Check the main input fuses. If

1.

If fuse (F1) quickly fails, per-

fans – no displays.

 

open, replace.

 

form the Auxiliary

 

2. Make certain that the input

 

Transformer Primary Wiring

 

 

Harness Test.

 

 

power switch (S1) is in the

 

 

 

 

 

 

 

“ON” position.

2.

If fuse (F1) does not fail, per-

 

3. Check for proper input voltage

 

form the Auxiliary

 

 

Transformer Test #1.

 

 

– must match the rating on the

 

 

 

 

 

 

 

machine nameplate.

 

 

 

4. Make certain the reconnect

 

 

 

 

panel is configured properly for

 

 

 

 

the applied voltage.

 

 

 

5. Check fuse (F1) in the recon-

 

 

 

 

nect panel. If faulty, replace

 

 

 

 

with 5-amp slow-blow fuse.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1- 800-833-9353.

POWER WAVE 450

Page 65
Image 65
Lincoln Electric SVM112-B service manual Troubleshooting Guide, Output Problems