Lincoln Electric SVM112-B K941-1 Remote Control KIT Trigger Circuit Test, Test Description

Models: SVM112-B

1 293
Download 293 pages 59.16 Kb
Page 191
Image 191

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-131

F-131

TROUBLESHOOTING & REPAIR

K941-1 REMOTE CONTROL KIT TRIGGER CIRCUIT TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

TEST DESCRIPTION

This test will determine if there are any faults in the 24 VAC trigger circuit between the Power Wave and the K941-1 Remote Control Kit.

MATERIALS NEEDED

Volt/Ohmmeter (Multimeter) 5/16" Nut driver

3/8" Nut driver

Short piece of jumper wire

Trigger Circuit Wiring Diagram – Figure F.50

This procedure takes approximately 30 minutes to perform.