Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
WATER COOLER REMOVAL AND REPLACEMENT (continued)
FIGURE F.60 - WATER COOLER LOCATION
2
1
3
1. WATER COOLER ACCESS DOOR (ON BACK PANEL)
2. WATER COOLING FITTINGS
3. CIRCUIT BREAKER
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
PROCEDURE
NOTE: These instructions may vary slightly with later model coolers. See instruc- tions included with cooler kit.
1.Remove main input supply power to the machine.
2.With the 3/8" nut driver, remove the 4 screws that hold the handle to the machine.
3.Remove the rubber gasket (cover seal) from the lift bail.
4.With the 5/16" nut driver, remove the sheet metal screws from the case top.
5.With the 5/16" nut driver, remove the screws holding the right and left case sides. Remove the case sides by lifting up and out.
6.Perform the Capacitor Discharge Proce- dure described earlier in this section of the manual.
WARNING
Before continuing with the test procedure, perform the capacitor discharge proce- dure to avoid electric shock.
7.After you have completed the capacitor dis- charge procedure for all four switch boards, use the 5/16" nut driver to remove the water cooler access door. See Figure F.60 for location.
8.With the 3/8" open end or socket wrench, remove the two water cooler assembly mounting screws. Slide the assembly to the left to better access the circuit breaker, which will be removed in a moment.
9.With the 5/16" nut driver, remove the two sheet metal screws holding the lower case back panel.