Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR | |||
|
|
|
FET MODULE REMOVAL AND REPLACEMENT (continued)
FIGURE F.73 - FET MODULE LOCATION
4
3
1
1. FET MODULE
2. PIEZO ALARM BUZZER
3. FET MODULE LOCKING BAR
4. RESISTORS
| 2 |
PROCEDURE | WARNING |
Return to Section TOC
Return to Master TOC
1.Remove main input supply power to the machine.
2.With the 3/8" nut driver, remove the 4 screws that hold the handle to the machine.
3.Remove the rubber gasket (cover seal) from the lift bail.
Before continuing with the test procedure, perform the capacitor discharge proce- dure to avoid electric shock.
Return to Section TOC
Return to Master TOC
4.With the 5/16" nut driver, remove the sheet metal screws from the case top.
5.With the 5/16" nut driver, remove the screws holding the right and left case sides. Remove the case sides by lifting up and out.
6.Perform the Capacitor Discharge Proce- dure described earlier in this section of the manual.
7.After you have completed the capacitor dis- charge procedure for all four switch boards, use the 5/16" nut driver to remove the two screws holding the printed circuit board cover in place. Slide the cover forward and lift up to remove it.
CAUTION
Be sure to follow the recommended
8.Remove the molex plugs from the PC boards except the display board.