| FUNCTION PROBLEMS |
|
|
The machine beeps without the | If the water cooler is enabled and | 1. | Perform the Auxiliary |
keys being pressed. | the flow switch inside the water |
| Transformer #2 Test. |
| cooler opens (due to inadequate | 2. The water cooler may be | |
| coolant flow rate), the machine | ||
|
| defective. Replace. | |
| indicates this by beeping. This |
| |
|
|
| |
| happens regardless of the overlay | 3. | Check the continuity of lead |
| placed on the machine. In this |
| #453, 454, 455 & 456 from |
| case, do the following. |
| plug J3 to J11. See wiring dia- |
| 1. Turn the machine off and on a |
| gram. |
|
|
| |
| couple of times and see if the | 4. | The display board may be |
| beeping continues. If the flow |
| faulty. Replace. |
| rate dropped momentarily, then |
|
|
| turning the machine off and on |
|
|
| eliminates the beeping. A |
|
|
| momentary drop in flow rate |
|
|
| could be due to a temporary |
|
|
| restriction in the water cooler |
|
|
| hose. |
|
|
| 2. Check the water cooler and |
|
|
| accessory hoses for kinks, |
|
|
| internal obstructions or block- |
|
|
| age, or ruptures. If such prob- |
|
|
| lems were found then correct |
|
|
| them. Turn the machine Off |
|
|
| and On to check if the beeping |
|
|
| has been eliminated. |
|
|
| 3. Check the water cooler fluid |
|
|
| level. Low coolant level could |
|
|
| cause the flow rate to drop. |
|
|
| 4. Prime the water cooler. Refer |
|
|
| to the Setup Overlay section |
|
|
| of this manual for instructions. |
|
|
|
|
|
|
CAUTION