ACCESSORIES
g. Install new pump and
•Do not apply any lubricant to pump’s drive coupling.
•Pump body is properly oriented with its strainer at the 6:00 position.
•Tighten
h.Attach coolant lines to QD and reser- voir.
i.Wipe dry all areas wetted by coolant. Dispose of towels in an environmentally responsible manner (see Recommended Coolants).
j.Reinstall cooler into machine.
4.Motor removal or replacement:
•Do not reuse the 4
5.Installing the fan:
•Slide onto motor shaft until the fan is located between 0.25 to 0.50 inches from the heat exchanger.
•Tighten set screw with 65 to 75
•Fan rotation is counterclockwise, as viewed from
•Fan pulls air through the heat exchanger, blows it over the motor, then exhausts it through the reservoir.