Lincoln Electric SVM112-B service manual Wire Feeder 1 Trigger Circuit Test

Models: SVM112-B

1 293
Download 293 pages 59.16 Kb
Page 172
Image 172

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-112

F-112

TROUBLESHOOTING & REPAIR

WIRE FEEDER 1 TRIGGER CIRCUIT TEST (continued)

FIGURE F.39 - DISPLAY BOARD PLUG LOCATIONS

J17

J16

J15

J14

J13 J12 J11

J10

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove main input supply power to the machine.

2.With the 3/8" nut driver, remove the 4 screws that hold the handle to the machine.

3.Remove the rubber gasket (cover seal) from the lift bail.

4.With the 5/16" nut driver, remove the sheet metal screws from the case top.

5.With the 5/16" nut driver, remove the screws holding the right and left case sides. Remove the case sides by lifting up and out.

6.Perform the Capacitor Discharge Procedure described earlier in this section of the manual.

WARNING

Before continuing with the test procedure, perform the capacitor discharge proce- dure to avoid electric shock.

7.After you have completed the capacitor discharge procedure for all four switch boards, remove the PC board cover. Use the 5/16" nut driver.

8.Remove plug J12 from the display board.

9.Place a jumper wire between pins C and D of wire feeder receptacle #1.

10.Remove the 5 leads ( 3 heavy and 2 small) T1, T2, T3 from main input contactor CR1. This is a safety precaution. It prevents high voltage from being put on the machine during the test. Wrap tape around the lead ends to insulate them and prevent them from touching.

POWER WAVE 450

Page 172
Image 172