INSTALLATION

Return to Section TOC

CAUTION

Failure to follow these instructions can cause immedi- ate failure of components within the welder.

GROUND CONNECTIONS

The frame of the welder must be grounded. A ground terminal marked with the symbol is located inside the reconnect/input access door for this purpose. See your

local and national electrical codes for proper ground- ing methods. See Figure A.2 for the location of the reconnect/input access door and related connection diagram.

wire sizes. Fuse the input circuit with the recom- mended super lag fuses or delay type circuit breakers. Choose an input and grounding wire size according to local or national electrical codes. Using fuses or cir- cuit breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents, even if the machine is not being used at high currents.

INPUT VOLTAGE RECONNECT

PROCEDURE

Welders are shipped connected for the highest input voltage listed on the rating plate. To change this con- nection for a different input voltage, refer to reconnect instructions in Figure A.2 and proceed according to the steps that follow for the appropriate voltage.

Return to Section TOC

Return to Master TOC

Return to Master TOC

INPUT POWER CONNECTIONS

Connect L1, L2, L3 according to the Input Supply Connection Diagram decal located on the reconnect/- input access door. See Figure A.2.

INPUT FUSE AND SUPPLY WIRE

CONSIDERATIONS

Refer to the Technical Specifications at the beginning of this Installation section for recommended fuse and

FIGURE A.2 - CONNECTION DIAGRAM ON RECONNECT/INPUT ACCESS DOOR

Return to Section TOC

Return to Master TOC

NOTE: Turn main input power to mthe machine OFF before perform- ing reconnect procedure. Failure to do so will result in damage to the machine. DO NOT switch the re- connect bar with machine power ON.

SAMPLE

REFER

 

 

SPECIFIC O

 

T

 

ONL

 

 

 

YOUR

DIAGRAM

 

 

Y

Return to Section TOC

Return to Master TOC

Also called “inverse time” or “thermal/magnetic” circuit breakers. These breakers have a delay in tripping action that decreases as the mag- nitude of the current increases.