} N.C. dry contact. 50mA max.

Digital Access Keypad Manual

WIRING, BASIC DIAGRAM

Digital Access Keypad Manual

PREPARING TO PROGRAM THE KEYPAD

To program the SK-1123-SQ, first determine the following information:

 

 

 

 

 

 

 

 

Tamper

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

DAP

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

Tamper

N.C.

 

 

 

 

 

 

 

 

Interlock

 

 

 

 

 

 

 

 

O/P 1

Inhibit

 

 

 

 

 

 

 

 

Door

Sensor

 

Relay

 

 

Relay

 

(--)

Ground

 

 

 

 

Duress

Output

 

 

1

 

 

2

 

 

 

 

 

 

 

 

Keypad

Active

 

 

 

 

 

 

 

 

(+)

(--)

 

Output #1

 

 

Output #2

 

Egress

12-24V

AC/DC

N.C.

COM

N.O.

N.C.

COM

N.O.

In

 

N.C. Tamper

N.C. Tamper

Interlock -- NPN transistor, used with second keypad1 (-) N.O. O/P #1 inhibit2

(-) N.C. Door position sensor input

(-) Common Ground - for use with interlock function Duress O/P -- Transistor Ground (-) 100mA@24VDC Keypad Active O/P -- Transistor Ground (-) 100mA@24VDC

1.The master code -- Allows the system administrator to program or operate the keypad.

2.The user code or codes -- Allows users to use the keypad's functions.

3.Configuration of the relays and outputs -- For relay output #1 and relay output #2, determine whether the output should operate from 1 to 999 seconds and then turn OFF (momentary mode), or turn ON/ OFF via the code (shunt mode).

4.Result of improper code entry (optional) -- Choose between a 30-second code lockout, duress output, a 15-minute code lockout, or no reaction.

* Note: When X X X X appears in the instructions, it indicates master code entry.

GETTING STARTED

A master code is required to program the keypad. The default master code is set to "0000." To change a forgotten master code, go to page 15 and follow the instructions for "MASTER CODE BYPASS" (DAP jumper).

Once the master code is set, review the programming options and decide exactly what the keypad will do, including the format of the user access codes as well as how the keypad responds via the relay output, buzzer and LEDs. Note that in every case the basic steps for programming are:

1.Enter the master code, followed by the * key, which puts you in programming mode.

2.Enter the programming options defined in the various sections as needed, followed by the # key.

3.Enter the * key again to exit programming mode.

Note: A rapid string of 5 beeps and/or 5 LED flashes indicates an error, while 2 beeps indicates that the entry has been accepted.

EG In - Egress -- N.O., ground (-)3

Relay #2 output -- N.O.

}

1A @ 28VDC, Normally

 

 

Relay #2 output -- COM

closed and normally open

Relay #2 output -- N.C.

dry contacts

Relay #1 output -- N.O.

 

5A @ 28VDC, Normally

 

 

 

Relay #1 output -- COM

 

closed and normally

Relay #1 output -- N.C.

}open dry contacts

(+)(-)} VAC/VDC12~24

4

 

 

1Mantrap control output -- Outputs ground (-) for five seconds after relay output #1 is activated, continues while the door is open.

2Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.

3Connect to optional N.O. push button or switch.

4For DC, connect to a regulated power supply with correct polarity, + to +, - to -. For AC, polarity is not important.

USER PROGRAMMING

ENTER PROGRAMMING MODE

 

Enter Master code

Confirm

Function

X X X X

*

Enter into programming mode

 

Note: For first-time use, Master code is

0 0 0 0

 

 

 

ADDING OR CHANGING MASTER AND USER CODES

WARNING -- Press the correct option key. If the option key is not used and a "0" is pressed after entering the Master

 

Code, it could accidentally reprogram the Master Code.

Option

User ID

Access code

Confirm

Function

0

 

4 to 8 digits

#

Change Master Code

1

00 to 99

4 to 8 digits

#

Set/change up to 100 User Codes for relay output #1, with duress feature

2

0 to 9

4 to 8 digits

#

Set/change up to 10 User Codes for relay output #2

Note: No user code may be the same as the master code.

Note: For User ID, key in the number of the user. For Access Code, type in the code for that particular user.

DELETE A USER

To delete a user who has left the company or who no longer has authority to enter the protected area:

1. Enter programming mode:

Enter Master code

Confirm

Function

X X X X

 

*

 

Enter into programming mode

2. Delete code:

 

 

 

 

Option

User ID

Confirm

Function

 

 

 

Deletes specific user ID from output #1

1

00 to 99

#

 

 

 

 

2

0 to 9

#

Deletes specific user ID from output #2

 

 

 

 

 

 

EXIT THE PROGRAMMING MODE BY PRESSING THE "*" KEY

Page 4

SECO-LARM U.S.A., Inc.

Page 13

Page 4
Image 4
SECO-LARM USA SK-1123-SQ warranty WIRING, Basic Diagram, Preparing to Program the Keypad, Getting Started, User Programming

SK-1123-SQ specifications

The SECO-LARM USA SK-1123-SQ is a versatile and reliable access control solution designed for various security applications. This compact and user-friendly device is widely used in residential and commercial settings due to its robust features, advanced technology, and ease of installation.

One of the standout characteristics of the SK-1123-SQ is its weather-resistant design, making it suitable for outdoor use. Equipped with a sturdy construction, it can effectively withstand various environmental conditions, ensuring consistent performance regardless of the weather. This makes it an ideal choice for securing entries, gates, and perimeters in diverse locations.

The device operates using a highly efficient electromagnetic locking system that provides a secure and controlled entry point. Designed for quick and reliable locking and unlocking, it supports both card and fob access methods, giving users flexibility in managing who can enter a designated area. This feature makes it compatible with various RFID standards, enabling seamless integration into existing security systems.

The SK-1123-SQ is equipped with an intuitive user interface that simplifies programming and operation. The device supports multiple access key fobs, allowing for managing different user levels efficiently. Furthermore, it features a built-in panic button, which can quickly unlock the door in case of emergencies, enhancing security and safety for all occupants.

In terms of installation, SECO-LARM has made significant strides in simplifying the process of setting up the SK-1123-SQ. With clear instructions and compatible mounting options, it can be installed in minimal time, making it an excellent choice for both professional installers and DIY enthusiasts.

Additionally, the SK-1123-SQ's compact design allows it to fit in tight spaces without sacrificing functionality, adding to its appeal in various installations. Its reliability is further backed by SECO-LARM's reputation for producing high-quality security products.

In summary, the SECO-LARM USA SK-1123-SQ stands out as a leading access control solution due to its weather-resistant design, various access methods, user-friendly functionalities, and hassle-free installation. With its advanced locking technology and commitment to safety, it represents an excellent investment for anyone looking to enhance their security measures.