Digital Access Keypad Manual
INSTALLER PROGRAMMING
These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.
| Enter Programming Mode | | (DEFAULT: 0 0 0 0 ) |
| Enter Master code | Confirm | Function |
| X X X X * | | * | | Enter into programming mode |
| *Key in the Master Code. | | |
| Note: For first-time use, Master code is | 0 0 0 0 |
| | | | |
| Data Refresh | | | |
| Option | | Confirm | Function | | |
| 8 | 9 0 | 1 | # | Clears all previously stored data. |
| | | |
| Configure Relay Outputs | | (DEFAULT: Momentary, 1-sec. output for both outputs) |
| Option | Output time | Confirm | Function |
| 4 | 0 | 1 to 999 | | # | Relay #1, momentary mode, from 1 to 999 seconds |
| 4 | 1 | | | | # | Relay #1, shunt mode (ON/OFF) |
| 5 | 0 | 1 to 999 | | # | Relay #2, momentary mode, from 1 to 999 seconds |
| 5 | 1 | | | | # | Relay #2, shunt mode (ON/OFF) |
| | | | |
| Wrong Code Lockout | | | (DEFAULT: 10 tries / 30 seconds) |
| Option | # of tries | Confirm | Function |
| 7 | 0 | | | # | After 10 successive wrong codes, 30-second lockout |
| 7 | 1 | | | # | After 10 successive wrong codes, Duress activated |
| 7 | 2 | 5 to 10 | # | After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code |
| 7 | 6 0 | 0 | | # | None of the above |
| | | |
| Door Forced-Open Alarm | | (DEFAULT: Disabled) |
| Option | Code entry | Confirm | Function |
| 8 | 0 | { | 1 | # | Door forced-open alarm is enabled |
| 0 | # | Door forced-open alarm is disabled |
| | |
| | | |
| Output Activation Announcer | | (DEFAULT: On) |
| Option | Code entry | Confirm | Function |
| | | { | 1 | # | 1-sec. beep notifies the user to open the door when the output relay is activated with the |
| 8 | 1 | | | user code or egress button. Use with a locking device which gives no sound when it |
| | | activates, such as a magnetic lock. |
| | | | |
| | | 0 | # | The beep is disabled, replaced by 2 short beeps for valid user codes. |
| | | | |
| User Code Entry Mode | | | (DEFAULT: Manual) |
| Option | Code entry | Confirm | Function |
| | | { | 1 | # | Auto Entry Mode is selected. The # key that follows the user code is NOT required in |
| 8 | 2 | | | code entry. The User Codes MUST be set to the same digit length as the Master Code, |
| | | from 4-8 digits. |
| | | | |
| | | 0 | # | Manual Entry Mode is selected. The # key that follows the user code is required in |
| | | | | | code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length. |
| | | | |
| Keypress Beeps | | | (DEFAULT: On) |
| Option | Code entry | Confirm | Function |
| 8 | 3 | { | 1 | # | Keypad beeps when a key is pressed. |
| 0 | | Silent operation -- keypad does not beep when a key is pressed. |
| | | # |
| | | |
| Door Propped Open Alarm Timer | | (DEFAULT: Off) |
| Option | Code entry | Confirm | Function |
| 9 | | | 0 | # | No door propped open alarm |
| | {1 to 999 | # | Allowable time from 1 to 999 seconds that the door can be left open before the door |
| | |
propped open alarm starts
Exit Programming Mode
Confirm Function
*Exits programming mode, returns keypad to normal operations
Digital Access Keypad Manual
UNIQUE FEATURES
•12-24V AC/DC universal power -- No programming or jumpers needed.
•Mantrap -- Each keypad can be used as a stand-alone keypad. However, the mantrap feature uses two keypads to protect an area with two doors by ensuring that only one door is open at a time. With the mantrap interlock functions, when a user keys in the code to open one door, a signal is sent to disable the second keypad, thereby preventing access through the second door until the first door is closed.
•Relay output #1 inhibit control -- Relay output #1 is typically used for a door strike. If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This increases the security of the protected premises during the time it is not expected to be occupied, such as during evening or weekend hours. An authorized user can enable or disable the inhibit control by using the code for relay output #2 at any time, depending on how installed.
•Door forced open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door to the protected premises is forced open without using a valid user code. The warning can be stopped only by closing the protected door.
•Door propped open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door is propped open after the allowed open time. The allowable open time is programmable. The warning stops when the door is re- closed.
•Auto or manual code entry checking:
•Auto code entry checking mode -- When all the user codes have the same number of digits, the keypad will activate automatically when the code is entered. There is no need to press the "#" key. This is convenient for the users.
•Manual code entry checking mode -- The user codes can vary in number of digits, and the user must press the "#" key when finished entering the code. This increases security.
•Keypad active output -- This NPN transistor open collector ground (-) output activates for 10 seconds when any key on the keypad is pressed. This can be used to trigger a video recorder or turn on a light, or to signal a guard that someone is entering the protected premises.
•Door auto relock -- The keypad will relock an open door either when the relock time expires or immediately after the door is closed, depending on which occurs first. This prevents unwanted "tailgate" entries, which can happen if an unauthorized person tries to follow an authorized person through the door.
•Duress output -- This NPN transistor open collector ground (-) output can be used to trigger a silent alarm if an authorized user is forced under duress to use the keypad. The duress output is activated by adding 2 to the first digit of user code 1. In this case, the protected door opens as it would normally, but a signal is quietly sent to a remote device to call for help without alerting the unauthorized person.
•Backlit keypad -- The keypad is backlit to increase nighttime visibility. For convenience, the lighting intensity will increase for 10 seconds after any key is pressed.