SECO-LARM USA SK-1123-SQ Digital Access Keypad Manual, Led Indicators, Buzzer And Led Signals

Models: SK-1123-SQ

1 8
Download 8 pages 17.99 Kb
Page 5
Image 5
PROGRAMMING NOTES

Digital Access Keypad Manual

PROGRAMMING NOTES

1.Master Code: The SK-1123-SQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or data should be programmed at the owner's discretion. However, to ensure security, program a new personal Master Code to replace the factory-set Master Code as soon as possible.

2.Factory defaults:

Digital Access Keypad Manual

SPECIFICATIONS

Power:

• Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.

Stand-by current drain -- 15mA @12VDC.

Active current drain (press keypad key) -- Under 45mA@12VDC.

Master code

0000

__________________________________________________________

User code length

4-8 digit

__________________________________________________________

Main relay output time

1 second

__________________________________________________________

Auxiliary relay output time

1 second

__________________________________________________________

Wrong code lockout

10 tries / 30 sec.

__________________________________________________________

Door forced open alarm

disabled

____________________________________________________________________________________________________________________

Output activation announcer

ON

__________________________________________________________

User code entry mode

manual

__________________________________________________________

Keypress beep

ON

__________________________________________________________

Door propped open alarm

OFF

__________________________________________________________

Silent operation

OFF

• Active current drain (one relay activated) -- Under 80mA@12VDC.

• Active current drain (two relays activated) -- Under 130mA@12VDC.

Outputs:

• Relay output #1 -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed

output or shunt (start/stop) output. Three terminals.

• Relay output #2 -- 1A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second momentary

output or shunt (start/stop) output. Three terminals.

3.Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the codes have the same number of digits, the keypad can be programmed for whether the # key must be used or not after entering the code (see programming, option 82, page 14).

The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer authorized to enter a protected area, without the need to teach the new code to all the other users.

Relay output #1 allows up to 100 user codes, and relay output #2 allows up to 10 user codes.

4.Using Duress Codes (Relay #1 only): Duress codes are used to activate a separate device silently to alert a guard or other personnel that a user is operating the keypad under threat. The keypad operates as normal, but a signal is sent to alert others.

Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code. For example:

User code 4468 can be entered as duress code 6468 User code 9843 can be entered as duress code 1843 User code 8181 can be entered as duress code 0181

NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user code. For example:

If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot be programmed.

Note: Once activated, the duress output continues until a correct user code is entered.

LED INDICATORS

Red LED -- Lights while output #2 is activated.

Amber LED -- Flashes to show the keypad status (see below).

Green LED -- Lights while output #1 is activated.

BUZZER AND LED SIGNALS

The keypad's built-in buzzer and the amber LED can signal the following:

 

STATUS

BUZZER TONES*

AMBER LED FLASHES

_____________________________________________________________________________________

1.

In programming mode

- - -

ON

_____________________________________________________________________________________

2.

Successful key entry

1 beep

1 flash

_____________________________________________________________________________________

3.

Successful code entry

2 beeps

2 flashes

_____________________________________________________________________________________

4.

Unsuccessful code entry

5 beeps

5 flashes

_____________________________________________________________________________________

5.

DAP jumper not replaced

Continuous beeps

Continuous flashes

_____________________________________________________________________________________

6.

In standby mode

- - -

1 flash in 2-sec. intervals

_____________________________________________________________________________________

7.

Output relay activated

1-sec. long beep**

- - -

NOTE: * The buzzer can be disabled through programming option 83, ref. pg. 14.

** The output relay activated beep can be disabled through programming option 81, ref. pg. 14.

• Tamper output -- 50mA @ 12VDC, N.C. output. Connect to tamper circuit of alarm control panel.

Two terminals.

• Keypad active or alarm output -- Transistor ground max. 100mA @ 24VDC. Switches to ground (-) for 10

sec. when a key is pressed (keypad active output), or switches to ground (-) to indicate a door was forced

open or propped open (alarm output). Single terminal.

• Mantrap (interlock) control output -- Outputs ground (-) for five seconds after relay output #1 is activated,

continues while the door is open. Use to disable a second keypad during this time. Single terminal.

• Ground output -- Steady ground (-), 100mA @ 24VDC. Single terminal.

• Duress output -- Transistor ground (-), 100mA @ 24VDC. If switches to ground (-) after the duress code

is entered. Single terminal.

Inputs:

Power -- 12-24Volts AC/DC. Two terminals.

Egress -- N.O., ground (-). Single terminal.

Door sensor input -- N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or closed, or connect to ground (-) if not used. Single terminal.

Relay output #1 disable input -- Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.

Single terminal.

Code Operation:

• Auto or manual code entry. Up to 100 user codes for relay output #1, up to 10 user codes for relay output #2. 111,110,000 possible user code combinations.

Auto refresh time during code entry:

Max. 10 seconds to enter each digit.

Max. 30 seconds to enter each code.

Dimensions (keypad with back box):

4-15/16" x 3-1/8" x 2" (125 x 78 x 51 mm).

Weight

18 oz. (510 grams).