92D0001

Gas Inlet & Manifold Pressures

  Natural LP
 MinimumInletPressure 5.5”w.c. 11.0”w.c.
 MaximumInletPressure 14.0”w.c. 14.0”w.c.
 ManifoldPressure 3.5”w.c. 10.0”w.c.

Gas Specification

  Max. Min.
Model Fuel Gas Control Input Input
ODGR400NV Nat. MillivoltHi/Lo 60,000 42,600
ODGR400PV Prop. MillivoltHi/Lo 60,000 44,000
ODGR500NV Nat. MillivoltHi/Lo 60,000 42,600
ODGR500PV Prop. MillivoltHi/Lo 60,000 44,000

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370 m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is rec-
ommended for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.

Valve Access

Valveaccesscanbeaccomplishedinoneoftwoways:
1.Removethefrontpaneljustbelowthefrontofthe
hearthpan.Thisisaccomplishedbyliftingonthe
panel.Toreplacethevalveaccesspanellineupthe
twopinswiththeholesinthesurroundbottomand
pushthepaneloverthefrontofthehearthpan.(Fig.
5)
2.Liftthebrickwiththelogoonit.(Fig.6)

ODGR400 / ODGR500

Certified to

CSA 4-96

FP1414
ODUVSR
valve access
11/24/03 djt
FP1414
Fig. 5Valveaccess.
FP1415lift brick access11/24/03 djt
LogoBrick
Fig. 6Liftbrickwithlogoonittoaccessvalve.
FP1415
1/2” (13 mm)
FP1642a
concrete install
9/06
NOTE:Wheninstallationis
onahard,flatsurface(such
asconcrete),thesurface
mustbesloped1/4"perfoot
awayfromanystructure.
Blocking
Hard,FlatSurface
(i.e.concrete) FP1642a
Fig. 7Exteriorchaseinstallation.