ODGR Series Outdoor Gas Fireplace

92D0001

General Information

Thisgasapplianceshouldbeinstalledbyaqualified

installerinaccordancewithlocalbuildingcodesandwith

currentCSA-B149.1InstallationcodesforGasBurning

AppliancesandEquipment.

FORU.S.AInstallationsfollowlocalcodesand/orthecur-

rentNational Fuel Gas Code. ANSI Z223.1/NFPA 54.

IntheCommonwealthofMassachusetts,allgasfittings

andinstallationofthisheatershallonlybedonebya

licensedgasfitterorlicensedplumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE

NOTE THE FOLLOWING:

1. Thisappliancegivesoffhightemperaturesandshouldbe
locatedoutofhightrafficareasandawayfromfurniture.
2. Childrenandadultsshouldbealertedtothehazardsofthe
highsurfacetemperaturesofthisapplianceandshouldstay
awaytoavoidburnsorignitionofclothing.
3. Childrenshouldbecarefullysupervisedwhentheyareinthe
sameroomasyourappliance.
4. Undernocircumstancesshouldthisappliancebemodified.
Partshavingtoberemovedforservicingshouldbereplaced
priortooperatingthisapplianceagain.
5. Installationandanyrepairstothisapplianceshouldbecar-
riedoutbyaqualifiedserviceperson.Aprofessionalservice
personshouldbecontactedtoinspectthisappliancean-
nually.Makeitapracticetohaveallofyourgasappliances
checkedannually.Morefrequentcleaningmayberequired
duetoexcesslintanddustfromcarpeting,beddingmaterial,
etc.
6. Controlcompartments,burnersandairpassagesinthisap-
plianceshouldbekeptcleanandfreeofdustandlint.Make
surethatthegasvalveandpilotlightareturnedoffbefore
youattempttocleanthisunit.
7. Keeptheareaaroundyourapplianceclearofcombustible
materials,gasolineandotherflammablevaporandliquids.
Thisapplianceshouldnotbeusedasadryingrackforcloth-
ing,norshouldChristmasstockingsordecorationsbehung
intheareaofit.
8. Undernocircumstancesshouldanysolidfuels(wood,coal,
paperorcardboardetc.)beusedinthisappliance.
9. Theflowofcombustionandventilationairmustnotbeob-
structedinanyway.
10.Whethertheapplianceisinstalleddirectlyoncarpeting,vinyl
tileoranycombustiblematerialotherthanwood,thisappli-
ancemustbeinstalledonametalorwoodpanelextending
thefullwidthanddepthoftheappliance.
11.Thisappliancerequiresadequateventilationandcombus-
tionairtooperateproperly.
12.Donotusethisapplianceifanyparthasbeenunderwater.
Immediatelycallaqualifiedservicetechniciantoinspectthe
applianceandtoreplaceanypartofthecontrolsystemor
gascontrolthathasbeenunderwater.
13.Inspecttheburnerbeforeeachuseoftheappliance.The
burnermustbereplacedpriortooperationifthereisevi-
dencetheburnerisdamaged.Useonlyburnerspecifiedby
manufacturer.
LP-cylinderenclosures,ifprovidedbytheconsumermustcon-
formtothedesignparametersasdetailedbelow.

Enclosures for LP-Gas Supply Systems

EnclosuresforLP-gassupplycylindersshallbeventilatedby
openingsatthelevelofthecylindervalveandatfloorlevel.The
effectivenessoftheopening(s)forpurposesofventilationshall
bedeterminedwiththeLP-gassupplycylinder(s)inplace.This
shallbeaccomplishedbyoneofthefollowing:
a.Onesideoftheenclosureshallbecompletelyopen;or
b.Foranenclosurehavingfoursides,atopandabottom:
1.Atleasttwoventilationopeningsatcylindervalvelevel
shallbeprovidedinthesidewall,equallysized,spacedat
180degrees(3.14rad),andunobstructed.Eachopening
shallhaveatotalfreeareaofnotlessthan1/2square
inchperpound(3.2sq.cm/kg)ofstoredfuelcapacityand
notlessthanatotalfreeareaof10squareinches(64.5
sq.cm).
2.Ventilationopening(s)shallbeprovidedatfloorleveland
shallhaveatotalfreeareaofnotlessthan1/2square
inchperpound(3.2sq.cm/kg)ofstoredfuelcapacityand
notlessthanatotalfreeareaof10squareinches(64.5
sq.cm).Ifventilationopeningsatfloorlevelareinaside
all,thereshallbeatleasttwoopenings.Thebottomof
theopeningsshallbeatfloorlevelandtheupperedgeno
morethan5inches(127mm)abovethefloor.Theopen-
ingsshallbeequallysized,spacedat180degrees(3.14
rad)andunobstructed.
3.Everyopeningshallhaveminimumdimensionssoasto
permittheentranceofa1/8inch(3.2mm)diameterrod.
Cylindervalvesshallbereadilyaccessibleforhandoperation.
Adoorontheenclosuretogainaccesstothecylindervalves
isacceptable,provideditisnon-lockingandcanbeopened
withouttheuseoftools.
Thereshallbeaminimumclearanceof2inches(51mm)
betweenthelowersurfaceoftheflooroftheLP-gassupply
cylinderenclosureandtheground.
Thedesignoftheapplianceshallbesuchthat(1)theLP-gas
supplycylinder(s)canbeconnected,disconnectedandthe
connectionsinspectedandtestedoutsidethecylinderenclo-
sure;and(2)thoseconnectionswhichcouldbedisturbedwhen
installingthecylinder(s)intheenclosurecanbeleaktested
insidetheenclosure.

Description

TheODGRSeriesareradiantfireplaces.Donotburnwoodor
othermaterialsintheseappliances.Eachmodelisavailable
withstandingpilotforusewithNaturalorPropanegasunits.
Reporttoyourdealeranypartsdamagedinshipment.
Adequatecombustionandventilationairmustbeprovided.The
flowofcombustionandventilationairMUSTNOTbeobstruct-
ed.
Provideadequateclearancesaroundtheairopeningintothe
combustionchamber;andadequateaccessibilityclearancefor
servicingandproperoperation.NEVERobstructthefrontopen-
ingoftheappliance.

This fireplace is not designed to be water tight.

Therefore, when installing this unit against an exte-

rior wall, the wall must be finished before setting unit

in place.