Remote Wall Switch

NOTE: Use an approved outdoor switch.

ODGR Series Outdoor Gas Fireplace

1.Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insu- lation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box.

2.Attach wire to switch and install switch into receptacle box. Attach cover plate to switch.

3.Connect wiring to gas valve. Refer to Figure 11.

CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply.

For lighting instructions, refer to Page 12.

NOTE: If glass doors are installed, the unit must be operated with the doors fully open. (Fig. 12) If the doors are not fully open, the thermodisk will auto- matically turn the unit off.

Pilot

On/Off

Switch

Thermodisk

TPTH

Valve

 

TP

 

TH

HV105

CAUTION: After the unit cools, the burner will automatically come on.

Fig. 11 Remote switch wiring.

OPEN

Correct

Wrong

MD706-7

Fig. 12 Correct door position during operation.

92D0001

Page 9
Image 9
Monessen Hearth ODGR400, ODGR500 manual Remote Wall Switch, Remote switch wiring