ODGR Series Outdoor Gas Fireplace

Troubleshooting

Nova SIT 820 Standing Pilot

START

Gas Supply On

YES

Pilot Lights with

Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main

Burner

YES

 

 

 

 

 

CHECK

NO

 

 

 

Supply Line Hooked up

 

 

 

 

 

 

 

Shutoff Valve Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lockout has engaged. Wait 60

 

 

 

 

 

seconds and try again.

 

 

 

 

 

Piezo not tight enough for good

 

 

 

 

 

ground.

NO

 

 

 

 

For spark at electrode while

 

 

depressing Piezo (Red Button)

 

 

 

 

 

 

 

 

 

 

1/8" gap to pilot hood needed.

 

 

 

 

 

All wiring connections

 

 

 

 

 

Replace Piezo Ignitor

 

 

 

 

 

Thermodisk

 

 

 

 

 

For Air in the lines

 

 

 

 

 

Thermopile needs a minimum

 

 

 

 

 

325mV. Adjust pilot flame height.

 

 

 

 

 

All wiring connections

NO

 

 

Replace Thermopile

 

 

 

 

 

 

Thermocouple needs a minimum

 

 

 

 

 

of 14mV.

 

 

 

 

 

Defective valve. Turn to pilot,

 

 

 

 

 

meter should read greater than

 

 

 

 

 

100mV.

 

 

 

 

 

Thermodisk

Wall switch is not turned on. Watch for grounded wires!

NO Thermopile needs a minimum 325mV

Plugged burner orifice Doors not fully open (Fig. 10)

System OK

FP396